2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PHOENIX RIGGING & ERECTING, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of PHOENIX RIGGING & ERECTING, LLC in 100 GRAPHIC PACKAGING INTERNATIONAL WAY, MACON, GA 31206 (NAICS 238990). OSHA activity number 339223786.

Watch Phoenix Rigging & Erecting, LLC — free Get an email when a new federal OSHA severe-injury report for Phoenix Rigging & Erecting, LLC is published. One employer, no account, unsubscribe in one click.
Site address
100 GRAPHIC PACKAGING INTERNATIONAL WAY
City
MACON
State
GA
ZIP
31206
Mailing
1855 DICKERSON DR., MABLETON, GA 30126
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
20
Ownership type
A

3 citations on file for this inspection.

1926.251 E02

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $6300.00 · Current $6300.00
29 CFR 1926.251(e)(2): The rated capacity of the synthetic webbing sling was exceeded.   On or about 07/20/2013 at 100 Graphic Packaging International Way, Macon, GA; an Ashley EE2-804 synthetic web sling used to support the lattice boom of a 200 ton Link-belt truck crane was loaded beyond its rated capacity, exposing employees to struck-by and fall hazards of 80 feet to the lower level.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $6300

1926.1403 B

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $6300.00 · Current $6300.00
29 CFR 1926.1403(b): The employer did not follow manufacturer procedures when an employer used synthetic slings during assembly or disassembly rigging:   On or about 07/20/2013 at 100 Graphic Packaging International Way, Macon, GA; during the disassembly of the lattice boom of a Link-belt 200 ton truck crane, the employer used an Ashley EE2-804 synthetic web sling to support the lattice boom and used their own employer procedures instead of Link-belt's procedures, exposing employees to struck-by and fall hazards of 80 feet to the lower level.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $6300

1926.1404 J

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $6300.00 · Current $0.00 Reduced
29 CFR 1926.1404(j): Manufacturer limitations on the maximum amount of boom supported only by cantilevering were exceeded:   On or about 07/20/2013 at 100 Graphic Packaging International Way, Macon, GA; an Ashley EE2-804 synthetic web sling was rigged to the lattice boom of a Link-belt 200 ton truck crane. The sling was located such that 113 feet of boom was cantilevered which exceeded the Link-belt limitation of 110 feet, exposing employees to struck-by and fall hazards of 80 feet to the lower level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

View PHOENIX RIGGING & ERECTING, LLC's full OSHA safety record →