FORT LAUDERDALE, FL —
OSHA Inspection: PHOENIX RIGGING & ERECTING LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of PHOENIX RIGGING & ERECTING LLC in 333 N NEW RIVER DR. EAST, FORT LAUDERDALE, FL 33301 (NAICS 238990). OSHA activity number 347393340.
Where did this inspection happen?
- Establishment
- PHOENIX RIGGING & ERECTING LLC
- Site address
- 333 N NEW RIVER DR. EAST
- City
- FORT LAUDERDALE
- State
- FL
- ZIP
- 33301
- Mailing
- 1855 DICKENSON DRIVE, MABLETON, GA 30126
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 7
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.1413 A01
- Issued
- Abate by
- Penalty
- Initial $11292.00 · Current $750.00 Reduced
General-duty citation text
29 CFR 1926.1413(a)(1): A competent person did not begin a visual inspection prior to each shift the equipment is used and/or did not complete the visual inspection before or during that shift. The inspection must consist of observation of wire ropes (running and standing) that are likely to be in use during the shift for apparent deficiencies, including those listed in paragraph (a)(2) of this section. (a) On or about April 04, 2024, at 333 N New River Drive East, Fort Lauderdale FL 33301, the shift inspection did not identify apparent deficiencies to include, but not limited to significantly corroded, and cracked, pins and bolts, and improperly applied (tightened) end connections, exposing employees to a fall greater than 300 feet to the ground.
Recent events (3)
- — F (S) $750
- — C (S) $11292
- — Z (S) $11292
1926.1423 H02
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1423(h)(2): During erecting, climbing, and dismantling work, the employer did not provide and ensure the use of fall protection equipment for employees who are on a walking/working surface with an unprotected side or edge more than 15 feet above a lower level. a) On or about April 04, 2024, at 333 N New River Drive East, Fort Lauderdale FL 33301, during climbing procedures the employer did not ensure the use of fall protection equipment for employees who were on a climbing platform, exposing employees to a fall greater than 300 feet to the ground.
Recent events (3)
- — F (S) $1000
- — C (S) $16131
- — Z (S) $16131
1926.1435 F02
- Issued
- Abate by
- Penalty
- Initial $11292.00 · Current $750.00 Reduced
General-duty citation text
29 CFR 1926.1435(f)(2): Pre-erection inspection. Before each crane component is erected, it must be inspected by a qualified person for damage or excessive wear. a) On or about April 04, 2024, at 333 N New River Drive East, Fort Lauderdale FL 33301, employer did not ensure pre inspection of each crane component including, but not limited to, the U-bolt (clamps/clips), bolts, pins, thimble, wire rope of the Terex Top Climbing System- Trolly Rail Guide (TRG) was adequately inspected by a qualified person for damage or excessive wear, exposing employees to a fall greater than 300 feet to the ground.
Recent events (3)
- — F (S) $750
- — C (S) $11292
- — Z (S) $11292
1926.1412 E03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1412(e)(3)(i): The monthly inspection items checked, the results of the inspection, the name and signature of the person conducting the monthly inspection, and the results of the inspection were not documented and maintained by the employe who conducts the inspection. (a) On or about April 04, 2024, at 333 N New River Drive East, Fort Lauderdale FL 33301, the employer did not ensure the monthly inspection documentation for Terex Top Climbing System did not include the inspection and results of the climbing frame system and its components such as but not limited to U-bolts (Cable Clamps), bolts, thimble and wire rope.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at PHOENIX RIGGING & ERECTING LLC
AUSTIN, TX—2014-08-08 00:00:00
PHOENIX RIGGING & ERECTING, LLC
MACON, GA—2013-07-22 00:00:00
PHOENIX RIGGING & ERECTING, LLC
View PHOENIX RIGGING & ERECTING LLC's full OSHA safety record →
More inspections in this industry (NAICS 238990)
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
EL PASO, TX—2026-07-09
RM CRANE & RIGGING LLC.
LAKEWOOD, WA—2026-07-08
WA317992018 - HARMON INC DBA HARMON SERVICE GLAZING INC
VICTOR, NY—2026-07-08
DIMARCO CONSTRUCTORS
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347393340.