Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DONNER STEEL WORKS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DONNER STEEL WORKS, INC. in 3900 INDUSTRIAL, LINCOLN, NE 68504 (NAICS 332999). OSHA activity number 339269128.

Watch Donner Steel Works, INC. — free Get an email when a new federal OSHA severe-injury report for Donner Steel Works, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3900 INDUSTRIAL
City
LINCOLN
State
NE
ZIP
68504
Mailing
3900 INDUSTRIAL, LINCOLN, NE 68504
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
13
Ownership type
A

6 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $1360.00
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:   The employer is failing to protect employees from fall hazards.  Employees are exposed to fall hazards greater than 4 feet to the concrete floor below due to the lack of standard guardrails in this area.
Recent events (1)
  • — Z (S) $1360

1910.141 A03

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $1020.00
29 CFR 1910.141(a)(3): The employer did not ensure that all places of employment were kept clean to the extent that the nature of the work allowed.   The employer is failing to ensure that employees are provided a sanitary workplace.  The restroom in the facility was unclean and toilet paper was strewn throughout the area.  The area also was infested with mice.
Recent events (1)
  • — Z (S) $1020

1910.141 A05

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(a)(5): Enclosed workplaces were not so constructed, equipped, and maintained as to prevent the entrance or harborage of rodents, insects, or other vermin:   The employer is failing to ensure that enclosed workplaces are constructed, equipped and maintained to prevent the harborage of rodents, insect or vermin.  There was evidence of mice droppings in the break room in the facility.  During the inspection it was observed that mice were running through the restroom and hallways.
Recent events (1)
  • — Z (S) $0

1910.252 B02 III

Serious Gravity 10 6 instances 10 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not required to wear appropriate goggles, to protect them from the rays when noncombustible or flameproof screens or shields were not used:   The employer is failing to provide an adequate number of welding screens in the welding areas to protect employees from ultraviolet rays during welding operations.  Nor are they requiring/providing appropriate personal protective equipment for employees adjacent to the welding operations in the facility.
Recent events (1)
  • — Z (S) $2800

1910.22 D01

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.   The employer is failing to protect the employees from struck-by hazards in the back storage room/mezzanine area.  Materials are being stored on the roof of this room.  The roof area has not been rated as to the safe weight which can be placed upon it.  This rating has not been posted to alert workers to the safe weight it will support
Recent events (1)
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   The employer is failing to provide Hazard Communication training to employees either during their initial assignment or whenever a new physical or health hazard that the employee has not previously been trained for has been introduced into their work area.  Some of the employees in the facility had not received training on the hazards of the chemicals/materials in the facility in which they could be potentially exposed.