Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DEVINEY CONSTRUCTION COMPANY, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of DEVINEY CONSTRUCTION COMPANY, INC. in 3974 I-55 SOUTH FRONTAGE ROAD, JACKSON, MS 39212 (NAICS 237130). OSHA activity number 339357642.

Watch Deviney Construction Company, INC. — free Get an email when a new federal OSHA severe-injury report for Deviney Construction Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3974 I-55 SOUTH FRONTAGE ROAD
City
JACKSON
State
MS
ZIP
39212
Mailing
P.O. BOX 6717, JACKSON, MS 39282
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
350
Ownership type
A

2 citations on file for this inspection.

1910.268 B07

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4200.00 Reduced
29 CFR 1910.268(b)(7): Approach distances to exposed energized overhead power lines and parts. The employer shall ensure that no employee approaches or takes any conductive object closer to any electrically energized overhead power lines and parts than prescribed in Table R-2, unless:  The employee is insulated or guarded from the energized parts (insulating gloves rated for the voltage involved shall be considered adequate insulation).  (a) Jobsite - On or about August 23, 2013, an employee was not wearing insulated electrical gloves while handling a conductor that had the possibility of making contact with high voltage overhead power lines.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1910.268 J04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.268(j)(4)(i): Derrick trucks and similar equipment shall not be operated with any conductive part of the equipment closer to exposed energized power lines than the clearances set forth in Table R-2 of this section.  (a) Jobsite - On or about August 23, 2013, employees were operating a digger derrick truck boom in close proximity of energized overhead power lines.  The employees did not comply with the established approach distances to exposed energized overhead power lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View DEVINEY CONSTRUCTION COMPANY, INC.'s full OSHA safety record →