PAYETTE, ID —
OSHA Inspection: NORTH PAYETTE MILLING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORTH PAYETTE MILLING INC. in 2133 NE 21ST AVENUE, PAYETTE, ID 83661 (NAICS 321992). OSHA activity number 339393845.
Where did this inspection happen?
- Establishment
- NORTH PAYETTE MILLING INC.
- Site address
- 2133 NE 21ST AVENUE
- City
- PAYETTE
- State
- ID
- ZIP
- 83661
- Mailing
- 2133 N. E. 21ST AVE., PAYETTE, ID 83661
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321992
- Employees
- 12
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition. a) On or about August 29, 2013, adjacent to the Lead Planer: Combustible materials such as wood shavings were not swept clean from the work area. Abatement certification is required for this item.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.252 A02 V
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.252(a)(2)(v): Where combustible materials such as paper clippings, wood shavings, or textile fibers were on the floor, the floor was not swept clean for a radius of 35 feet (10.7 m). Combustible floors were not kept wet, covered with damp sand, or protected by fire-resistant shields. a) On or about August 29, 2013, adjacent to the Lead Planer: During welding operations, combustible materials such as wood shavings were not swept clean for a radius of 35 feet. Wood shavings were within 10 feet of welding operations. Although wet methods were utilized, combustible materials were guarded by a combustible cardboard barrier. Abatement was completed for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or about August 29, 2013, in the workplace: The employer had not conducted a periodic inspection of the energy control procedures in the workplace. Lockout is performed on equipment such as the Lead Planer on the Notching Line. Abatement certification is required for this item.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.147 C07 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls was acquired by employees. a) On or about August 29, 2013, in the workplace: The employer did not provide lockout/tagout training to employees involved in energy control procedures on the Lead Planer of the Notching Line. Abatement was completed for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). a) On or about August 29, 2013, in the workplace: The employer did not ensure that operators of the Toyota Forklift, Model O2-05F630, had completed training required by 29 CFR 1910.178. Abatement certification is required for this item.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.213 D01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Each circular crosscut table saw was not guarded by a hood which met all the requirements of paragraph (c)(1) of this section for hoods for circular ripsaws. Each circular hand-fed table saw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut. a) On or about August 29, 2013, on the manufacturing floor by Pole J: A table saw utilized for cross-cuts of wood to be utilized as spacers for packaging was missing an overhead guard. Abatement certification is required for this item.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. a) On or about August 29, 2013, in the workplace: Unused openings in the Circuit Breaker Panel corresponding to the lights of the facility was missing knockouts, and was open to the environment. Abatement certification is required for this item.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. a) On or about August 29, 2013, in the workplace: The Circuit Breaker Panel corresponding to the lights of the facility was not legibly marked to indicate its purpose. Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more was not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures. a) On or about August 29, 2013, Control Panel for the Chop Saw on the Notching Line: The control panel was propped open 4 inches exposing operators to live parts. Abatement was completed for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 321992)
STRATFORD, WI—2026-07-13 00:00:00
STRATFORD HOMES LIMITED PARTNERSHIP
BAINBRIDGE ISLAND, WA—2026-07-09 00:00:00
WA317992071 - TIETON CABIN COMPANY LLC
NAVASOTA, TX—2026-06-26 00:00:00
CHAMPION HOME BUILDERS, INC.
EAST MONTPELIER, VT—2026-06-18 00:00:00
HUNTINGTON HOMES, INC.
HUDSON, WI—2026-06-12 00:00:00
US LBM HOLDINGS, LLC
More inspections in ID
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
CARRILLO CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
SEVY BROTHERS CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
CBH HOMES
BOISE, ID—2026-07-16 00:00:00
RAYMOND MANAGEMENT COMPANY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339393845.