Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,783,325Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: LOSURDO FOODS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LOSURDO FOODS, INC. in 34 UNION STREET, HEUVELTON, NY 13654 (NAICS 311513). OSHA activity number 339408676.

Watch Losurdo Foods, INC. — free Get an email when a new federal OSHA severe-injury report for Losurdo Foods, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
LOSURDO FOODS, INC.
Site address
34 UNION STREET
City
HEUVELTON
State
NY
ZIP
13654
Mailing
34 UNION STREET, HEUVELTON, NY 13654
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311513
Employees
50
Ownership type
A

14 citations on file for this inspection.

1910.22 C

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, drains, etc.:  a)  Boiler Room, on or about 9/11/13:  A floor drain, approx. 12 inches by 5 feet in length  and 4 inches deep was not guarded.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.23 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:  a)  Front Loading Dock, on or about 9/11/13:  Open sided floor at the loading dock was not provided with a midrail in one section.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.24 H

Serious Gravity 1 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:  a)  Front Loading Dock, on or about 9/11/13:  A fixed stairway at the loading dock with five risers was not provided with a midrail on the right side descending.  b)  Ricotta Room, on or about 9/11/13:  A fixed stairway at the Double O's with 7 risers was not provided with midrails.  c)  Ricotta Room, on or about 9/11/13:  A fixed stairway at the ricotta kettles with 5 risers was not provided with midrails.   Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.36 D01

Serious Gravity 10 4 instances 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2940.00 Reduced
29 CFR 1910.36(d)(1): Exit doors were locked or fastened, preventing free escape from inside the building:  a)  Warehouse, on or about 9/11/13:  Four exit doors in the warehouse were double locked at the door handle and with a latch.  Abatement documentation must be submitted for this item.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.37 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  a)  Warehouse, on or about 9/11/13:  There were no exit directional signs to indicate the direction of travel to the nearest exit.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.37 B05

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  a)  Compressor Room, on or about 9/11/13:  A door in the room was not marked as to its actual use.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B06

Serious Gravity 1 7 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  a)  Boiler Room, on or about 9/11/13:  Two exit signs were not illuminated by a reliable light source.  b)  Warehouse, on or about 9/1/13:  There were five exit signs that were not illuminated by a reliable light source.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B07

Serious Gravity 1 7 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(7): Each exit sign did not have the word "Exit" in plainly legible letters not less than six inches (15.2 cm) high, with the principal strokes of the letters in the word "Exit" not less than three fourths of an inch (1.9 cm) wide:  a)  Boiler Room, on or about 9/11/13:  Two exit signs located at each exit door were not properly marked.  b)  Warehouse, on or about 9/11/13:  There were five exit signs located at each exit door that were not properly marked.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1785.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a)  Maintenance Dept., on or about 9/11/13:  Rotating chuck on a Rockwell/Delta drill press was not guarded.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a)  Fresh Mozzarella Room, on or about 9/11/13:  Point of operation at the die cutter on a Holmatic heat sealer machine was not guarded.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 I02

Serious Gravity 1 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.219(i)(2): Revolving surfaces of shaft coupling(s) were not covered by a safety sleeve:  a)  Pasteurizer Room, on or about 9/11/13:  Shaft coupling on a booster pump was not adequately guarded.  b)  Fresh Mozzarella Room, on or about 9/11/13:  Shaft coupling on a pump for the CMC machine was not adequately guarded.  c)  Whey Room, on or about 9/11/13:  Shaft coupling on a pump to the whey tank was not adequately guarded.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  Cheese Loading Dock, on or about 9/11/13:  Flexible cord providing current to a Clute 500-S stretch wrap machine was being used as permanent wiring.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.147 C04 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items A-D of this section:      a)  At the establishment, on or about 9/11/13:  There were no written machine specific procedures for various machinery outlining the rules and techniques to be utilized for each piece of equipment, including, but not limited to compressors, heaters, pumps, wrappers, fillers, cooling units, etc.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F01

Other-than-serious 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a)  Pasteurizer Room, on or about 9/11/13:  Three disconnect switches on the wall were not labeled as to their purpose.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View LOSURDO FOODS, INC.'s full OSHA safety record →