Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GUAM METAL WORKS AND WELDING SERVICES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GUAM METAL WORKS AND WELDING SERVICES in TAMUNING MOBILE GAS STATION LOT 2111-3-1, TAMUNING, GU 96913 (NAICS 238160). OSHA activity number 339459117.

Watch Guam Metal Works AND Welding Services — free Get an email when a new federal OSHA severe-injury report for Guam Metal Works AND Welding Services is published. One employer, no account, unsubscribe in one click.
Site address
TAMUNING MOBILE GAS STATION LOT 2111-3-1
City
TAMUNING
State
GU
ZIP
96913
Mailing
P.O. BOX 10763, TAMUNING, GU 96931
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.351 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $689.00 · Current $517.00 Reduced
29 CFR 1926.351(b)(1): Arc welding or cutting cable(s) were not of the completely insulated, flexible type, capable of handling the maximum current requirements of the work in progress:  At the front side of the project site on November 4, 2013, the + Holder cable of the Shanghai Robtol Tool Manufacturing Co., Ltd. NSA 250 Inverter Arc Welding machine was not completely insulated.
Recent events (2)
  • — I (S) $516.75
  • — Z (S) $689

1926.351 E

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $810.00 · Current $608.00 Reduced
29 CFR 1926.351(e): Arc welding or cutting operation(s) were not shielded by noncombustible or flame proof screens to protect employees and other persons working in the vicinity from the direct rays of the arc:  At the front side of the project site on November 4, 2013, arc welding operations involving the Shanghai Robtol Tool Manufacturing Co., Ltd. NSA 250 were not shielded by noncombustible or flame proof screens to protect employees and other persons working in the vicinity from the direct rays of the arc.
Recent events (2)
  • — I (S) $607.5
  • — Z (S) $810

View GUAM METAL WORKS AND WELDING SERVICES's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339459117.