1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: WIN-CON ENTERPRISES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WIN-CON ENTERPRISES, INC. in 3781 LOOP 337, NEW BRAUNFELS, TX 78130 (NAICS 444190). OSHA activity number 339473530.

Watch Win-Con Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for Win-Con Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3781 LOOP 337
City
NEW BRAUNFELS
State
TX
ZIP
78130
Mailing
483 N. WEST END AVENUE, NEW BRAUNFELS, TX 78130
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
Employees
57
Ownership type
A

5 citations on file for this inspection.

1910.215 B09

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $2066.00 · Current $1240.00 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.   On or about 6 November 2013, and at times prior thereto, five employees within the fabrication area would use a table-mounted grinder on lifting bars in which the tongue guard for the abrasive wheel was more then 1/4th inch from the wheel surface, exposing the employees to the hazard of being struck by flying objects.
Recent events (2)
  • — I (S) $1239.6
  • — Z (S) $2066

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $2066.00 · Current $1240.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.   On or about 6 November 2013, and at times prior thereto, two employees within the crate building area utilized compressed air that was at approximately 60 psi at the nozzle to clean out excess sawdust buildup in and around a chop saw, exposing the employees to the hazard of being struck by flying debris or objects.
Recent events (2)
  • — I (S) $1239.6
  • — Z (S) $2066

1910.305 B01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $5670.00 · Current $3402.00 Reduced
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed.   On or about 6 November 2013, and at times prior thereto, employees working within the fabrication area utilized an outlet receptacle box in which the energized conductors entering the box were not effectively closed with approximately 1.5 inches of wires visible, exposing the employees using the receptacle to an electrical hazard of approximately 120 volts.
Recent events (2)
  • — I (S) $3402
  • — Z (S) $5670

1910.305 G02 III

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.   On or about 6 November 2013, and at times prior thereto, employees within the weatherseal area used on a daily basis a pole-mounted fan that had exposed internally sheathed wires up to approximately 2 inches, exposing the employees to an electrical hazard of approximately 120 volts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 J02 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(j)(2)(i): All 15- and 20-ampere attachment plugs and connectors (with dead-front construction) were not constructed so that there were no exposed current-carrying parts.   On or about 6 November 2013, and at times prior thereto, three employees working within the Prepping area utilized a two plug receptacle outlet that had both faceplate damage and an open knockout, exposing the employees to an electrical hazard of approximately 120 volts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View WIN-CON ENTERPRISES, INC.'s full OSHA safety record →