Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAYAN CONSTRUCTION MANAGEMENT GROUP, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MAYAN CONSTRUCTION MANAGEMENT GROUP, INC in MIAMI INTERNATIONAL AIRPORT CONCOURSE E, MIAMI, FL 33142 (NAICS 238990). OSHA activity number 339495160.

Watch Mayan Construction Management Group, INC — free Get an email when a new federal OSHA severe-injury report for Mayan Construction Management Group, INC is published. One employer, no account, unsubscribe in one click.
Site address
MIAMI INTERNATIONAL AIRPORT CONCOURSE E
City
MIAMI
State
FL
ZIP
33142
Mailing
986 GIBRALTAR ROAD, KEY LARGO, FL 33037
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 D12 III

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(d)(12)(iii): Wire rope clips used on suspension scaffold ropes were not inspected and retightened to the manufacturer's recommendations:  On or about 11/21/2013, at the above addressed jobsite, two employees operating a suspension scaffold were removing beams from the exterior of an 8-story hotel, whereas the outrigger tieback clips were not inspected and retightened to the manufactures' torque recommendations after initial loading, and at the start of each work shift, and after the initial and each subsequent assembly.  PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
  • — Z (S) $2800

1926.502 D16 III

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  On or about 11/21/13, at the above addressed jobsite, employees working from a suspension scaffold were removing exterior beams of an 8-story hotel whereas they were using a retractable lanyard attached to shock absorbing lanyard exposing them to a free fall hazard of more than 6 feet.
Recent events (1)
  • — Z (S) $2000

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  On or about 11/21/13, at the above addressed jobsite, the employer did not provide adequate training to their employees to recognize fall hazards while operating a suspension scaffold attached to a fall protection system that was rigged to allow an employee to free fall more than six (6) feet.
Recent events (1)
  • — Z (S) $2000

1926.1052 C01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  On or about 11/21/13, at the above addressed site, employees were using a stairway with four risers approximately 36" in height to access the roof area, whereas the stairway was not equipped with a stairrail system.
Recent events (1)
  • — Z (S) $1200