CHARLESTOWN, MA —
OSHA Inspection: WHITTEMORE-WRIGHT COMPANY, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of WHITTEMORE-WRIGHT COMPANY, INC. in 62 ALFORD STREET, CHARLESTOWN, MA 02129 (NAICS 316110). OSHA activity number 339513400.
Where did this inspection happen?
- Establishment
- WHITTEMORE-WRIGHT COMPANY, INC.
- Site address
- 62 ALFORD STREET
- City
- CHARLESTOWN
- State
- MA
- ZIP
- 02129
- Mailing
- 62 ALFORD STREET, CHARLESTOWN, MA 02129
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 316110
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: Boiler Room: Employer did not provide and ensure the use of protective shield/barrier or thermal protective clothing to protect employees from thermal burns while performing inspections and maintenance of the boiler such as the blow-down operation. On October 23, 2013, an employee sustained a first and second degree thermal burn on the legs, torso and arms while performing a blow-down of the boiler.
Recent events (2)
- — I (S) $1600
- — Z (S) $2000
1910.262 C09
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.262(c)(9): Pipe(s) carrying steam or hot water for process or servicing textile machinery, within 7 feet of the floor or working platform, were not covered with heat insulating material or otherwise guarded: Boiler Room: Piping for the boiler that carries hot water and steam including, but not limited to, the blow down pipes that were located within 7 feet of the work platform were not insulated or properly guarded to protect employees from thermal burns when they were engaging in operations such as blow-down. On October 23, 2013, an employee sustained a first and second degree thermal burn on the legs, torso and arms while performing a blown-down of the boiler.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
More inspections in this industry (NAICS 316110)
MILWAUKEE, WI—2026-05-07
D.R. DIEDRICH & CO., LTD.
RED WING, MN—2025-09-30
109975 - RED WING SHOE COMPANY INC DBA SBFOOT TANNING COMPA
RED WING, MN—2025-09-30
109972 - RED WING SHOE COMPANY INC DBA SBFOOT TANNING COMPA
JOHNSTOWN, NY—2025-07-16
ADIRONDAC LEATHER, INC.
WATERLOO, IA—2025-07-11
WATERLOO PROCESSING, LLC
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source