Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JOINT BASE ELMENDORF-RICHARDSON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOINT BASE ELMENDORF-RICHARDSON in 673 FORCE SUPPORT SQUADRON 8515 SHARP AVE, JBER, AK 99506 (NAICS 493110). OSHA activity number 339525420.

Watch Joint Base Elmendorf-Richardson — free Get an email when a new federal OSHA severe-injury report for Joint Base Elmendorf-Richardson is published. One employer, no account, unsubscribe in one click.
Site address
673 FORCE SUPPORT SQUADRON 8515 SHARP AVE
City
JBER
State
AK
ZIP
99506
Mailing
10441 KUTER AVE, JBER, AK 99506
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
2
Ownership type
D

4 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:    673rd FSS Warehouse:  On or about 15 April 2014 and times prior thereto, abatement certification for citation 1 item 3 of unsafe and unhealthful conditions contained in inspection number 952542 was not completed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.    673 FSS, Bldg. 8515, Warehouse:  On or about 13 December 2013 and times prior thereto 120 volt electrical panel, located on south wall, missing a knock out.  This condition exposed employees to an electrical shock and burn hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).  673 FSS, Bldg. 8515, Warehouse: On or about 13 December 2013 and times prior thereto, a 100 foot, orange extension cord had cut insulation.  This condition exposed employees to an electrical shock and burn hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1960.8 A

Serious Gravity 10 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1960.8(a):  The Agency head did not furnish employment and a place of employment to each employee that were free from recognized hazards that caused or were likely to cause death or serious physical harm.    673 FSS Bldg. 8515, Warehouse:  On or about 13 December 2013 and times prior thereto seven 3 foot by 9 foot storage racks were not secure to the wall or floor. Pallet racks are located in a seismically active zone. Pallet storage racks did not have the maximum safe load limits posted. This condition exposed employees to a struck by hazard.
Recent events (4)
  • — I $0
  • — Z $0
  • — I (S) $0

View JOINT BASE ELMENDORF-RICHARDSON's full OSHA safety record →