NIAGARA FALLS, NY —
OSHA Inspection: PRECISION PROCESS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRECISION PROCESS INC in 2111 LIBERTY DRIVE, NIAGARA FALLS, NY 14304 (NAICS 333298). OSHA activity number 339526931.
Where did this inspection happen?
- Establishment
- PRECISION PROCESS INC
- Site address
- 2111 LIBERTY DRIVE
- City
- NIAGARA FALLS
- State
- NY
- ZIP
- 14304
- Mailing
- 2111 LIBERTY DRIVE, NIAGARA FALLS, NY 14304
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333298
- Employees
- 57
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.36 H02
- Issued
- Abate by
- Penalty
- Initial $1575.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.36(h)(2): Outdoor exit route(s) were not covered where snow or ice was likely to accumulate. (Exception: Not required where employer can demonstrate that snow or ice will be removed before it can present a hazard) a) On or about 12/18/13, in the machine shop's north exits, two outdoor exit routes were blocked by accumulated snow. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $1575
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $2625.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 12/18/13, in the production areas, employer did not develop and document machine-specific lockout/tagout procedures for Bruderer Stamping Presses. b) On or about 12/18/13, in the production areas, a lockout/tagout procedure was not utilized when changing dies on the Bruderer Stamping Presses. c) On or about 12/18/13, in the production areas, a lockout/tagout procedure was not utilized when unjamming parts inside the Bruderer Stamping Presses. d) On or about 12/18/13, in the production areas, a lockout/tagout procedure was not utilized when changing blades on a Peerless Horizontal Band Saw. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1600
- — Z (S) $2625
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $2625.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 12/18/13, in the establishment, employer did not conduct periodic inspections of their machine-specific lockout/tagout procedures for machines such as, but not limited to: Mazak CNC Mills, CNC Lathes and Horizontal Band Saws since 10/04/2010. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1600
- — Z (S) $2625
1910.215 B09
- Issued
- Penalty
- Initial $1339.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On or about 12/18/13, in the manual machine shop area, a Dayton 10" Bench Grinder's tongue guard was adjusted to 3/4 inch. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $800
- — Z (S) $1339
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about 12/18/13, in the machine shop areas, compressed air hoses used to clean chips and coolant off parts inside the CNC Mills, CNC Lathes, Manual Mills and Manual Lathes were above 30 p.s.i. as follows: a) Mazak CNC Lathe #058's compressed air hose was used at 50 p.s.i. b) Mazak CNC Mill #002's compressed air hose was used between 50-60 p.s.i. c) Mazak CNC Mill #004's compressed air hose was used at 70 p.s.i. d) Mazak CNC Mill #5000's compressed air hose was used at 60 p.s.i. e) Mazak CNC Mill #001's compressed air hose was used at 70 p.s.i. f) Millport Manual Mill #7's compressed air hose was used at 70 p.s.i. h) Acer Manual Mill #29's compressed air hose was used at 50 p.s.i. i) Manual Lathe #12's compressed air hose was used at 80 p.s.i. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1200
- — Z (S) $2100
More inspections at PRECISION PROCESS INC
NIAGARA FALLS, NY—2024-08-01 00:00:00
PRECISION PROCESS INC
View PRECISION PROCESS INC's full OSHA safety record →
More inspections in this industry (NAICS 333298)
LOUISVILLE, KY—2026-04-22
69044 - DURR SYSTEMS LLC
TUALATIN, OR—2026-03-13
317743514 - ASCENTEC ENGINEERING LLC
STATESVILLE, NC—2026-01-29
160427 - J. C. STEELE AND SONS, INC.
MINNEAPOLIS, MN—2025-09-17
109881 - KURT MANUFACTURING COMPANY INC
TUALATIN, OR—2025-08-28
317741663 - ASCENTEC ENGINEERING LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339526931.