Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BURNETT ENTERPRISES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BURNETT ENTERPRISES in 1414 CHESTNUT STREET, COSHOCTON, OH 43812 (NAICS 238120). OSHA activity number 339550881.

Watch Burnett Enterprises — free Get an email when a new federal OSHA severe-injury report for Burnett Enterprises is published. One employer, no account, unsubscribe in one click.
Establishment
BURNETT ENTERPRISES
Site address
1414 CHESTNUT STREET
City
COSHOCTON
State
OH
ZIP
43812
Mailing
26 1ST AVENUE SW, ETNA, OH 43018
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.451 E08

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $1540.00 Reduced
29 CFR 1926.451(e)(8): Direct access to or from another surface shall be used only when the scaffold is not more than 14 inches (36 cm) horizontally and not more than 24 inches (61 cm) vertically from the other surface.    a. At the BP gas station work site, an employee had accessed the top of the canopy from the scaffold which was greater than 14 inches from the canopy, and the scaffold deck was greater than 24 inches below the canopy, thereby exposing employees to a fall hazard of 12 to 15 feet.
Recent events (3)
  • — F (S) $1540
  • — C (S) $3080
  • — Z (S) $3080

1926.760 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $0.00 Reduced
29 CFR 1926.760(a)(1): Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems.  a. At the BP gas station work site, the employer failed to provide and ensure the employee working on top of the canopy had fall protection, such as, but not limited to a guardrail system, or personal fall arrest system. The employee was exposed to a fall hazard of 15 feet.
Recent events (3)
  • — F (S) $0
  • — C (S) $3080
  • — Z (S) $3080

1926.1051 A

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1320.00 · Current $660.00 Reduced
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.    a. At the BP gas station work site, the employer had set up a mobile scaffold with integrated ladder, however the base support was raised to high resulting in a break in elevation from the ground to the first rung of the ladder being approximately 32 inches. The employees were exposed to a fall hazard of 32 inches.
Recent events (3)
  • — F (O) $660
  • — C (S) $1320
  • — Z (S) $1320

1926.100 A

Repeat Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $4400.00 · Current $2200.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.    a. On January 15, 2013, employees working at the BP in Coshocton were working on the ground without head protection under a mobile scaffold while an employee worked from the scaffold and another employee worked on the canopy for the gas station. Employees were exposed to a struckby hazard.      Burnett Enterprises was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 387542, citation number 1, item number 1 and was affirmed as a final order on May 10, 2013, with respect to a workplace located at 965 Poplar Street Nelsonville, OH 45764.
Recent events (3)
  • — F (R) $2200
  • — C (R) $4400
  • — Z (R) $4400

1926.451 G04 I

Repeat Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $6160.00 · Current $3080.00 Reduced
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.    a. At the BP gas station work site, the employer was using a mobile scaffold which did not have a guardrail system in the front of the scaffold facing the work, thereby exposing the employee to a fall hazard of approximately 12 feet.    b. At the BP gas station work site, the employer was using a mobile scaffold which did not have mid rails on the ends of the platform thereby not meeting the criteria of a guardrail system. The employees were exposed to a fall hazard of approximately 12 feet.    Burnett Enterprises was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 387542, citation number 1, item number 2/b and was affirmed as a final order on May 10, 2013, with respect to a workplace located at 965 Poplar Street Nelsonville, OH 45764.
Recent events (3)
  • — F (R) $3080
  • — C (R) $6160
  • — Z (R) $6160

1926.452 W06 II

Repeat Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6160.00 · Current $3080.00 Reduced
29 CFR 1926.452(w)(6)(ii): The height to base width ratio of the scaffold during movement is two to one or less, unless the scaffold is designed and constructed to meet or exceed nationally recognized stability test requirements such as those listed in paragraph (x) of Appendix A to this subpart (ANSI/SIA A92.5 and A92.6);    a. At the BP gas station work site, the employer was riding on a mobile scaffold that was approximately 12 feet in height and a width of four feet, resulting in a three to one ratio; thereby exposing employees to a fall hazard of 12 feet.    Burnett Enterprises was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.452(w)(6)(v), which was contained in OSHA inspection number 387542, citation number 1, item number 2c and was affirmed as a final order on May 10, 2013, with respect to a workplace located at 965 poplar Street Nelsonville, OH 45764.
Recent events (3)
  • — F (R) $3080
  • — C (R) $6160
  • — Z (R) $6160

View BURNETT ENTERPRISES's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339550881.