Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NTS INCORPORATED OF TEXAS

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of NTS INCORPORATED OF TEXAS in 10 MILES N.E. OF KELTON WHEELER COUNTY, WHEELER, TX 79096 (NAICS 811310). OSHA activity number 339570913.

Watch NTS Incorporated OF Texas — free Get an email when a new federal OSHA severe-injury report for NTS Incorporated OF Texas is published. One employer, no account, unsubscribe in one click.
Site address
10 MILES N.E. OF KELTON WHEELER COUNTY
City
WHEELER
State
TX
ZIP
79096
Mailing
15810 W. BUS I40, SHAMROCK, TX 79079
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
43
Ownership type
A

3 citations on file for this inspection.

1910.147 D05 II

Serious Gravity 10 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4900.00 Reduced
29 CFR 1910.147(d)(5)(ii): Where there was a possibility of re-accumulation of stored energy to a hazardous level, verification of isolation was not continued until the servicing or maintenance was completed, or until the possibility of such accumulation:    On or about January 29, 2014, NTS Incorporated of Texas exposed employees in the process of changing valves on an existing pipeline to fire/explosion hazards.  The employer did not ensure that verification of isolation of hydrocarbons and hydrocarbon vapors was continued until the maintenance operation was completed.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.147 F03 I

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4900.00 Reduced
29 CFR 1910.147(f)(3)(i): When maintenance was performed by a crew, craft, department or other group, a procedure was not utilized that afforded the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device:      On or about January 29, 2014, the employer did not utilize a procedure to lockout the section of pipe being worked on that afforded the employees protection against the release of hazardous energy afforded by an individual lockout.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.307 C

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4900.00 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:    On or about January 29, 2014, the employer did not ensure that spark-producing equipment was not used in a hazardous (classified) area, exposing employees to flash fire and explosion hazards.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

RNWBL

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339570913.