Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: TONAWANDA COKE CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TONAWANDA COKE CORPORATION in 3875 RIVER ROAD, TONAWANDA, NY 14150 (NAICS 324199). OSHA activity number 339571903.

Watch Tonawanda Coke Corporation — free Get an email when a new federal OSHA severe-injury report for Tonawanda Coke Corporation is published. One employer, no account, unsubscribe in one click.
Site address
3875 RIVER ROAD
City
TONAWANDA
State
NY
ZIP
14150
Mailing
P.O. BOX 5007 3875 RIVER ROAD, TONAWANDA, NY 14151
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324199
Employees
126
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 3 instances 6 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970:    a) The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees working/walking in the enclosed counterweigh area were exposed to asphyxiation from the release of flammable Coke Oven Gas (COG) from the rupture disc of the coke side manifold.  b) The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees working/walking in the enclosed counterweigh area were exposed to explosion and fire hazards from the release and ignition of flammable Coke Oven Gas (COG) from the rupture disc of the coke side manifold.  ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • — Z (S) $7000

1910.307 C

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, or approved for the hazardous (classified) location, or safe for the hazardous (classified) location:  a) On or about 01/31/14, in the counterweight area where Coke Oven Gas(COG) manifolds were located, electrical equipment and wiring such as, but not limited to: 120 volts electrical boxes and transformers for lighting, stack controls, reversal alarm, 480 volts dicarbonizing air disconnect switch, 120 volts L.B. White Tradesman K170 Forced Air Kerosene Heaters were not approved for Class I, Division 2 location.   ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • — Z (S) $0

View TONAWANDA COKE CORPORATION's full OSHA safety record →