Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ROBINSON BROTHERS ENVIRONMENTAL, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROBINSON BROTHERS ENVIRONMENTAL, INC. in 375 US HIGHWAY 151 (BUSINESS), PLATTEVILLE, WI 53818 (NAICS 562910). OSHA activity number 339585812.

Watch Robinson Brothers Environmental, INC. — free Get an email when a new federal OSHA severe-injury report for Robinson Brothers Environmental, INC. is published. One employer, no account, unsubscribe in one click.
Site address
375 US HIGHWAY 151 (BUSINESS)
City
PLATTEVILLE
State
WI
ZIP
53818
Mailing
220 RAEMISCH ROAD, WAUNAKEE, WI 53597
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
120
Ownership type
A

3 citations on file for this inspection.

1926.850 A

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4050.00 · Current $4050.00
29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the conditions of the framing floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations.(a)    On or about February 12, 2014, a written engineering survey of the structure was not performed prior to employees engaging in demolition operations.
Recent events (3)
  • — F (O) $4050
  • — C (S) $4050
  • — Z (S) $4050

1926.859 G

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.859(g): During demolition, continuing inspections by a competent person shall be made as the work progresses to detect hazards resulting from weakened or deteriorated floors, or walls, or loosened material. No employee shall be permitted to work where such hazards exist until they are corrected by shoring, bracing, or other effective means.  On or about February 12, 2014, during demolition operations, a competent person did not perform inspections of the structure to detect hazards such as but not limited to: exposure to un-braced / un-shored flooring.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.856 A

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4050.00 · Current $4050.00
29 CFR 1926.856(a): Mechanical equipment shall not be used on floors or working surfaces unless such floors or surfaces are of sufficient strength to support the imposed load.    On or about February 12, 2014 a structural collapse occurred when a Caterpillar 345C (serial number PJW00642) Backhoe was operated over a floor that could not support the load.
Recent events (3)
  • — F (O) $4050
  • — C (S) $4050
  • — Z (S) $4050

View ROBINSON BROTHERS ENVIRONMENTAL, INC.'s full OSHA safety record →