Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BISON ELECTRICAL SERVICES, CORP.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of BISON ELECTRICAL SERVICES, CORP. in 400 LINCOLN PARKWAY, BUFFALO, NY 14216 (NAICS 238210). OSHA activity number 339586919.

Watch Bison Electrical Services, Corp. — free Get an email when a new federal OSHA severe-injury report for Bison Electrical Services, Corp. is published. One employer, no account, unsubscribe in one click.
Site address
400 LINCOLN PARKWAY
City
BUFFALO
State
NY
ZIP
14216
Mailing
4228 RIDGE LEA ROAD, AMHERST, NY 14226
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.34 C

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $1020.00 · Current $0.00 Reduced
29 CFR 1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency.     a) On or about 2/13/14 at former church being renovated into apartments at 400 Lincoln Pkwy., Buffalo, NY: Employees used passageways in the lower level to move to different areas and as a pathway to exits.  In three places, this path went through wall openings. The height of those openings were 58 inches or less and employees could walk right into the wall if there was an emergency and they had to exit the building.   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $1020
  • — Z (S) $1020

1926.403 B02

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1020.00 · Current $0.00 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a) On or about 2/13/14 in lower level apt.# 10, at former church being renovated into apartments at 400 Lincoln Pkwy., Buffalo, NY: A metal 2-receptacle 120 volt-ac outlet box was supported only by Romex cable coming out of a breaker box. This is prohibited by the National Electric Code.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $1020
  • — Z (S) $1020

1926.405 B01

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:    a) On or about 2/13/14 in lower level apt.# 10, at former church being renovated into apartments at 400 Lincoln Pkwy., Buffalo, NY:  A metal 2-receptacle 120 volt-ac outlet box was supported only by Romex cable coming out of a breaker box. Electrical equipment and an extension cord were plugged into each receptacle on the box. A circular "knock-out" opening was not covered.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 I03

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $1020.00 · Current $500.00 Reduced
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees:        a) On or about 2/13/14 at former church being renovated into apartments at 400 Lincoln Pkwy., Buffalo, NY: Employees used passageways in the lower level to move to different areas, and as a pathway to exits. In three places, this path went through wall openings. On the floor beneath each wall opening there was a rectangular hole approx. 7 in. wide x 35 in. long x 28 in. deep. These holes were covered with 2 or more pieces of plywood which were not secured in place.      NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $500
  • — C (S) $1020
  • — Z (S) $1020

1926.502 I04

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard:        a) On or about 2/13/14 at former church being renovated into apartments at 400 Lincoln Pkwy., Buffalo, NY: Employees used passageways in the lower level to move to different areas, and as a pathway to exits. In three places, this path went through wall openings. On the floor beneath each wall opening there was a rectangular hole approx. 7 in. wide x 35 in. long x 28 in. deep. These holes were covered with 2 or more pieces of plywood which were not color coded nor marked with the word "Hole" or "Cover".      NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.1052 C01 I

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $1020.00 · Current $0.00 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    a) On or about 2/13/14 at former church being renovated into apartments at 400 Lincoln Pkwy., Buffalo, NY: Employees were exposed to a potential fall down the stairway leading from just inside the entrance door near the southeast corner, to the lower level of the building. The stairway was enclosed on both sides and a handrail was not installed on at least one side.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $1020
  • — Z (S) $1020

1926.1052 C01 II

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:    a) On or about 2/13/14 at former church being renovated into apartments at 400 Lincoln Pkwy., Buffalo, NY: Employees were exposed to a potential fall down the stairway leading to apartment #1 in the front part of the building. The stairway had four risers and was not enclosed on either side. No stairrail system was present on each side.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

View BISON ELECTRICAL SERVICES, CORP.'s full OSHA safety record →