WILLIAMSTOWN, PA —
OSHA Inspection: ZEMCO TOOL & DIE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ZEMCO TOOL & DIE in 113 SOUTH WEST STREET, WILLIAMSTOWN, PA 17098 (NAICS 334419). OSHA activity number 339611048.
Where did this inspection happen?
- Establishment
- ZEMCO TOOL & DIE
- Site address
- 113 SOUTH WEST STREET
- City
- WILLIAMSTOWN
- State
- PA
- ZIP
- 17098
- Mailing
- 113 SOUTH WEST STREET, WILLIAMSTOWN, PA 17098
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334419
- Employees
- 20
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Zemco Tool & Die, 113 South West Street, Williamstown, Pennsylvania - Employees performed servicing and maintenance activities, such as die-changing, mold changing, and installing new motors, on a variety of machinery and equipment, including, but not limited to, the Bruderer AG Typ BSTA 20 four-post high-speed mechanical stamping press and the Toyo Machinery & Metal Co. Ltd. Plastar T1-90GS plastic injection molding machine, and the employer did not develop and implement an energy control program, consisting of machine specific energy control procedures, group lockout/tagout, testing and positioning procedures, periodic inspections, and employee training, exposing employees to hazards of getting caught-in and struck-by moving machine parts, on or about November 1, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Zemco Tool & Die, 113 South West Street, Williamstown, Pennsylvania - Employees performed servicing and maintenance activities, such as die-changing, mold changing, and installing new motors, on a variety of machinery and equipment, including, but not limited to, the Bruderer AG Typ BSTA 20 four-post high-speed mechanical stamping press and the Toyo Machinery & Metal Co. Ltd. Plastar T1-90GS plastic injection molding machine, and the employer did not develop and implement machine specific energy control procedures, exposing employees to hazards of getting caught-in and struck-by moving machine parts, on or about November 1, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 D09 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.217(d)(9)(i): The employer did not establish a die setting procedure for mechanical power presses that would ensure compliance with 29 CFR 1910.217(c): (a) Press Room - Employees changed dies on various mechanical power presses, including, but not limited to, the Bruderer AG Typ BSTA 20 four-post high-speed mechanical stamping press, and the employer did not develop and implement die-setting procedures, exposing employees to hazards of getting caught-in and struck-by moving machine parts, on or about January 2, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Press Room - A homemade extension cord, consisting of a metal knockout box with two receptacles attached to a flexible cord, which supplied power to the tool safety and the de-reeler for the Bruderer AG Typ BSTA 20 four-post high-speed mechanical stamping press, was not installed in accordance with the box's listing, labelling, or certification in that the knockout box was not securely and rigidly mounted to the building or other support structure, exposing employees to injurious contact with electrical current, on or about January 2, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
More inspections in this industry (NAICS 334419)
BINGHAMTON, NY—2026-07-15 00:00:00
I3 ASSEMBLY, LLC
POUGHKEEPSIE, NY—2026-07-13 00:00:00
MARCO BOARD HOUSE, INC.
GRANTSVILLE, UT—2026-07-13 00:00:00
JABIL, INC.
JACKSON, MN—2026-07-10 00:00:00
111568 - TECHNICAL SERVICES FOR ELECTRONICS INC
YORK, PA—2026-06-29 00:00:00
IDSI LLC
More inspections in PA
PHILADELPHIA, PA—2026-07-16 00:00:00
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16 00:00:00
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16 00:00:00
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15 00:00:00
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15 00:00:00
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339611048.