NEENAH, WI —
OSHA Inspection: LUCIO PEREZ
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of LUCIO PEREZ in 1241-1243 CAMERON CIRCLE, NEENAH, WI 54956 (NAICS 236115). OSHA activity number 339668212.
Where did this inspection happen?
- Establishment
- LUCIO PEREZ
- Site address
- 1241-1243 CAMERON CIRCLE
- City
- NEENAH
- State
- WI
- ZIP
- 54956
- Mailing
- 901 OUTAGAMIE ST., APPLETON, WI 54914
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) On April 9, 2014, employees working at a residence at 1241-1243 Cameron Circle, Neenah, WI 54956, were not protected from falling approximately 12 feet from the eve of the roof by the use of a fall protection system as outlined above.
Recent events (1)
- — Z (S) $2800
1926.502 D06 III
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.502(d)(6)(iii): Unless the snap hook is a locking type and designed for the following connections, snap hooks shall not be engaged to a Dee-ring to which another snap hook or other connector is attached: a) Two employees were sharing one anchor point on separate lifelines. The anchor was designed for only one lifeline.
Recent events (1)
- — Z (S) $2800
1926.502 D15
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) There were two anchors that were not capable of supporting at least 5,000 pounds per employee attached since the anchors were used with only one nail fastened on each side of the anchor.
Recent events (1)
- — Z (S) $0
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) The employer did not ensure that each employee engaged in roofing work had been trained in the fall protection requirements to identify and implement conventional or personal fall protection while working on a residential roof 12 feet and greater from the lower ground level.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grab rail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support: a) On April 9, 2014 the portable fiberglass ladder was not extended 3 feet above the edge of the roof and was not secured at the top of the ladder to prevent displacement.
Recent events (1)
- — Z (S) $1200
More inspections at LUCIO PEREZ
ELKHART LAKE, WI—2019-05-09 00:00:00
LUCIO PEREZ
SHEBOYGAN, WI—2018-09-07 00:00:00
LUCIO PEREZ
SHEBOYGAN, WI—2017-07-20 00:00:00
LUCIO PEREZ
SHEBOYGAN, WI—2016-06-24 00:00:00
LUCIO PEREZ
EDINBURG, TX—2010-10-27 00:00:00
LUCIO PEREZ
View LUCIO PEREZ's full OSHA safety record →
More inspections in this industry (NAICS 236115)
PACIFIC PALISADES, CA—2026-07-17 00:00:00
BLUE LABEL CONSTRUCTION, INC.
SHAVER LAKE, CA—2026-07-17 00:00:00
LEVON ZEKIAN
MERIDIAN, ID—2026-07-17 00:00:00
CBH HOMES
PHILADELPHIA, PA—2026-07-16 00:00:00
CENTER CITY CONSTRUCTION AND DEVELOPMENT, LLC
PHILADELPHIA, PA—2026-07-16 00:00:00
OLD COUNTRY CONSTRUCTION, LLC
More inspections in WI
GREEN BAY, WI—2026-07-17 00:00:00
PTS CONTRACTORS, INC.
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339668212.