Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROCKET II DISTRIBUTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROCKET II DISTRIBUTION, INC. in 2521 BRUNSWICK AVE. BLDG. B, LINDEN, NJ 07036 (NAICS 488510). OSHA activity number 339679292.

Watch Rocket II Distribution, INC. — free Get an email when a new federal OSHA severe-injury report for Rocket II Distribution, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2521 BRUNSWICK AVE. BLDG. B
City
LINDEN
State
NJ
ZIP
07036
Mailing
2521 BRUNSWICK AVE. BLDG. B, LINDEN, NJ 07036
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488510
Employees
13
Ownership type
A

6 citations on file for this inspection.

1910.36 G02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.36(g)(2): An exit access was not at least 28 inches (71.1 cm) wide at all points.     a) Rocket II Distribution, Linden NJ/ Shipping receiving area- The exit access did not have at least 28 inches of egress. When measured the exit access only had 23 inches of egress exposing the employees to a fire hazard.       Observed on or 04/17/2014
Recent events (3)
  • — R (S) $1000
  • — C (S) $2000
  • — Z (S) $2000

1910.37 A03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.37(a)(3): Exit routes were not free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route.     a) Rocket II Distribution, Linden/ Shipping receiving area- The exit route was obstructed with pallets of merchandise exposing the employees to a fire hazard.       Observed on or about 04/17/2014
Recent events (3)
  • — R (S) $1000
  • — C (S) $2000
  • — Z (S) $2000

1910.110 B06 VI

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.110(b)(6)(vi): Readily ignitable material such as cardboard was not removed within 10 feet of any container.    a) Rocket II Distribution, Linden NJ- Readily ignitable material such as cardboard was placed next to the LP gas system and was not placed 10 feet away from the containers.      Observed on or 04/17/2014
Recent events (3)
  • — R (S) $1000
  • — C (S) $2000
  • — Z (S) $2000

1910.110 E04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.110(e)(4)(iii): .LP gas container(s) installed on internal combustion engine vehicles were not securely mounted to prevent jarring loose, slipping or rotating:    a) Rocket II Distribution, Linden NJ/ Shipping Receiving Area- the LP gas cylinder located on the back side of the Toyota LP gas sit down type (fork lift) power industrial truck was not properly secured.  The bracket in the middle of the cylinder was broken.  The Toyota sit down type power industrial truck was last used on or about April 16, 2014.      Observed on or 04/17/2014
Recent events (3)
  • — R (S) $1000
  • — C (S) $2000
  • — Z (S) $2000

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.151(c): The eyewash station was not made readily available in case of an emergency.       a) Rocket II Distribution, Linden NJ- The eyewash station was not made readily available if an employee is exposed to injurious corrosive materials. The eyes wash was blocked by cardboard boxes and storage material.       Observed on or 04/17/2014
Recent events (3)
  • — R (S) $800
  • — C (S) $1600
  • — Z (S) $1600

1910.303 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.    a) Rocket II Distribution, Linden NJ/ Southwest corner of warehouse- Electrical panel boxes rated 600 volts or less were blocked by storage materials and a minimum of 30 inches of space was not maintained.      Observed on or 04/17/2014