Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ECOSHEL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ECOSHEL, INC. in 100 LEVESQUE MILL ROAD, ASHLAND, ME 04732 (NAICS 321999). OSHA activity number 339767808.

Watch Ecoshel, INC. — free Get an email when a new federal OSHA severe-injury report for Ecoshel, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ECOSHEL, INC.
Site address
100 LEVESQUE MILL ROAD
City
ASHLAND
State
ME
ZIP
04732
Mailing
115 MIDDLE STREET, SUITE 300, PORTLAND, ME 04101
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
6
Ownership type
A

8 citations on file for this inspection.

1926.102 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2240.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:   Ashland Mill - Employees operating the Bostitch pneumatic nailer were not wearing eye protection.
Recent events (2)
  • — I (S) $2240
  • — Z (S) $2800

1926.100 A

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:   Ashland Mill - Protective helmets were not worn by employees exposed to a pneumatic nailer and overhead hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 B01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1600.00 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters (GFCI)for personal protection:   Ashland Mill - The blue and green extension cords plugged into the Generac generator were not protected with GFCI.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2000

1926.405 A02 II I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1600.00 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points:   Ashland Mill - Protection was not provided to avoid damage to three extension cords which passed through a doorway.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2000

1926.405 J02 II

Serious Gravity 5 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(j)(2)(ii): A receptacle installed in a wet location was not designed for the location:   Ashland Mill - The three green extension cords, each having one receptacle, were exposed to rain and were not designed for wet locations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.602 C01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1920.00 Reduced
29 CFR 1926.602(c)(1)(ii): Modifications or additions affecting the safe operation of the equipment were made without the manufacturer's written approval:   Ashland Mill - The propane tank frame and clamp on the Yale forklift had been modified with wood and bungee cords.
Recent events (2)
  • — I (S) $1920
  • — Z (S) $2400

1926.602 C01 VI

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.602(c)(1)(vi): Industrial truck(s) in use did not meet the applicable requirements of design, construction, stability, inspection, testing, maintenance, and operation, as defined in American National Standards Institute (ANSI) B56.1-1969, Safety Standards for Powered Industrial Trucks:   In the following instances powered industrial trucks did not met the requirements of ANSI B56.1-1969:   a) Ashland Mill - The parking brake was not set on the unattended Yale forklift.  b) Ashland Mill - The horn on the Yale forklift was not operational.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.602 C01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1600.00 Reduced
29 CFR 1926.602(c)(1)(vii):  A safe place to ride was not provided on powered industrial truck(s):   Ashland Mill - An employee inside a cart was lifted by the forks of a Toyota forklift.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2000

View ECOSHEL, INC.'s full OSHA safety record →