Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MEJIA GLASS RAISING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MEJIA GLASS RAISING in 1 COLLEGE ST., YOUNG HARRIS, GA 30582 (NAICS 238150). OSHA activity number 339786253.

Watch Mejia Glass Raising — free Get an email when a new federal OSHA severe-injury report for Mejia Glass Raising is published. One employer, no account, unsubscribe in one click.
Establishment
MEJIA GLASS RAISING
Site address
1 COLLEGE ST.
City
YOUNG HARRIS
State
GA
ZIP
30582
Mailing
1028 JUNIPER ST., DURHAM, NC 27701
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238150
Employees
18
Ownership type
A

3 citations on file for this inspection.

1926.501 B04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $2520.00 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around hole.        On or about May 21, 2014:        a) Employees were exposed to fall hazards of approximately 15.4 feet while working around a skylight opening without the use of fall protection measures to include guard rails, covers or personal fall arrest systems.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

1926.501 B10

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    On or about May 21, 2014:    a) Employees engaged in skylight frame assembly on a low slope roof were exposed to fall hazards at the top edge of the structure of approximately 16.7 feet, when the employer failed to properly install and maintain any form of perimeter fall protection measures to include a warning line for the employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1926.503 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1440.00 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  On or about May 21, 2014:  a) Employees exposed to fall hazards of approximately 15.4 while preparing an opening for skylight frame and 16.7 feet, while working on a low slope roof assembling skylight frame, failed to recognize and/or minimize the fall hazard, when the employer did not provide a training program for the employees.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339786253.