Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRAXTON MANUFACTURING COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BRAXTON MANUFACTURING COMPANY, INC. in 169 CALLENDER ROAD, WATERTOWN, CT 06795 (NAICS 332116). OSHA activity number 339886640.

Watch Braxton Manufacturing Company, INC. — free Get an email when a new federal OSHA severe-injury report for Braxton Manufacturing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
169 CALLENDER ROAD
City
WATERTOWN
State
CT
ZIP
06795
Mailing
P.O. BOX 429, WATERTOWN, CT 06795
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
170
Ownership type
A

7 citations on file for this inspection.

1910.213 A09

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $2700.00 · Current $1350.00 Reduced
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219:  Carpentry Shop:  On, or about, August 7, 2014, the drive belt provided on the Rockwell table saw was not provided with a guard.  Ref. 29 CFR 1910.219(e)(3)(i)
Recent events (2)
  • — I (S) $1350
  • — Z (S) $2700

1910.213 B03

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4500.00 · Current $2250.00 Reduced
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:  Carpentry Shop:  On, or about, August 7, 2014, the Rockwell table saw was not provided with a drop-out starter or equivalent device to prevent the machine from re-starting following a power outage.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4500

1910.213 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  Carpentry Shop:  On, or about,  August 7, 2014, a hood guard had not been provided on the Rockwell table saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4500.00 · Current $2250.00 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut:  Carpentry Shop: On, or about, August 7, 2014, a lower blade guard had not been provided on the DeWalt radial arm saw.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4500

1910.213 H04

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator:   Carpentry Shop:  On, or about, August 7, 2014, the DeWalt radial arm saw had not been provided with an operable mechanism to return the saw to its resting position when released.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3600.00 · Current $1800.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Carpentry Shop:  On, or about, August 7, 2014, a Genie shop vac labeled for residential use was used to catch the waste material generated from the Rockwell table saw.  Also, the wood chips and dust that was present in the shop vac collection container was determined to be a Class II combustible dust.  The owners manual for the unit stated that it was not designed to clean up flammable or explosive materials.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3600

1910.303 B01 I

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(1)(i): Electrical equipment was not free from recognized hazards likely to cause death or serious physical harm, in that the employer did not ensure that the electrical equipment had adequate electrical insulation:  Carpentry Shop:  On, or about, August 7, 2014, the outer insulation provided on the power cord for the Rockwell table saw was damaged and wrapped with electrical tape.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BRAXTON MANUFACTURING COMPANY, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339886640.