RIDGELAND, MS —
OSHA Inspection: SHUCKER'S PIANO & OYSTER BAR, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SHUCKER'S PIANO & OYSTER BAR, INC. in 116 CONESTOGA ROAD, RIDGELAND, MS 39157 (NAICS 722210). OSHA activity number 339896532.
Where did this inspection happen?
- Establishment
- SHUCKER'S PIANO & OYSTER BAR, INC.
- Site address
- 116 CONESTOGA ROAD
- City
- RIDGELAND
- State
- MS
- ZIP
- 39157
- Mailing
- 116 CONESTOGA ROAD, RIDGELAND, MS 39157
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 722210
- Employees
- 20
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.101 B
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $666.00 Reduced
General-duty citation text
29 CFR 1910.101(b): Section 3.4.4 Compressed Gas Association, Inc. Pamphlet P-1-1965, as adopted by 29 CFR 1910.6(k): Compressed gas cylinder(s) in storage and in use were not properly supported to prevent them from being knocked over: (a) Dry Storage - On or about August 07, 2014 employees were exposed to unrestrained compressed nitrogen cylinders.
Recent events (2)
- — I (S) $666
- — Z (S) $1200
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $666.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) Site wide - On or about August 08, 2014 employees were handling corrosive without protective gloves and appropriate eye protection.
Recent events (2)
- — I (S) $666
- — Z (S) $1200
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $887.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) Kitchen - On or about August 07, 2014 employees were exposed to injurious corrosive materials without an eye wash being ready accessible.
Recent events (2)
- — I (S) $887
- — Z (S) $1600
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1108.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about August 07, 2014 employees were exposed to live electrical parts from wire hanging out of electrical outlet.
Recent events (2)
- — I (S) $1108
- — Z (S) $2000
1910.305 B01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: (a) Bud Cooler - On or about August 08, 2014 the outlet box had a missing knockout thereby exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 IX
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $666.00 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded: (a) Bud Cooler room - On or about August 08, 2014 the light in the cooler was not protected from accidental contact or breakage.
Recent events (2)
- — I (S) $666
- — Z (S) $1200
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $887.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Site Wide - On or about August 08, 2014 a written hazard communication program was not developed for chemicals used in the work place. Employees were working with chemicals such as compressed gases, bleach, and corrosives.
Recent events (2)
- — I (S) $887
- — Z (S) $1600
More inspections in this industry (NAICS 722210)
SAIPAN, MP—2021-06-22 00:00:00
JTM CORPORATION
RENO, NV—2020-10-02 00:00:00
LOC NGUYEN
BONDUEL, WI—2020-10-01 00:00:00
RED ROOSTER CAFE & CATERING LLC
FENTON, MI—2020-09-29 00:00:00
LEOS CONEY ISLAND
ALTUS, OK—2020-08-28 00:00:00
FRED'S STEAKHOUSE AND SALOON
More inspections in MS
LAUREL, MS—2026-07-01
THERMO-KOOL
HORN LAKE, MS—2026-07-01
NEWLY WEDS FOODS, INC.
GAUTIER, MS—2026-07-01
DOUBLE R GAUTIER, LLC
OLIVE BRANCH, MS—2026-06-30
HYVE SOLUTIONS
GAUTIER, MS—2026-06-30
STEVE WILSON ENTERPRISE
Source