OSHA Inspection: LARRY MCMURRAN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LARRY MCMURRAN in 6311W. FITCH AVE., CHICAGO, IL 60646 (NAICS 237110). OSHA activity number 339936056.

Watch Larry Mcmurran — free Get an email when a new federal OSHA severe-injury report for Larry Mcmurran is published. One employer, no account, unsubscribe in one click.
Establishment
LARRY MCMURRAN
Site address
6311W. FITCH AVE.
City
CHICAGO
State
IL
ZIP
60646
Mailing
477 N. NORTHWEST HWY., PARK RIDGE, IL 60068
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
5
Ownership type
A

9 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $700.00 Reduced
29 CFR 1926.20(b)(1): Program(s) were not initiated and/or maintained to comply with applicable safety and health provisions:      a) The employer did not maintain programs to provide for compliance with the OSH Act and control or minimize the safety and health hazards associated with trenching and excavation work that his employees are required to perform.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $700
  • — C (S) $2000
  • — Z (S) $2000

1926.21 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:        a) Employer did not instruct or provide instruction to employees in the recognition and avoidance of unsafe conditions and the regulations applicable to their work environment to control or minimize the hazards associated with their work.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.651 K01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(k)(1):  Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems:       a)  Employer did not provide a competent person to conduct inspections where employees were exposed to the hazards associated with trenching and excavation work.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $560.00 Reduced
29 CFR 1926.100(a):  Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:      a)  Employees working in a trench were not wearing protective helmets where there was a possible danger of head injury from falling objects.     No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (S) $560
  • — C (S) $1600
  • — Z (S) $1600

1926.651 I03

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures:     a)  Employees were not protected from the possible collapse of the surfaces adjacent to the trench that were undermined.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $700.00 Reduced
29 CFR 1926.651(j)(2):  Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:      a) Employees were not protected from the hazard of falling or rolling excavated material that was placed and kept at the edge of the trench.      No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (S) $700
  • — C (S) $2000
  • — Z (S) $2000

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $980.00 Reduced
29 CFR 1926.652(a)(1):  Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c):      a)  Employees were not protected from the hazard of cave-in while working in a trench measuring approximately 9.3 feet in depth.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $980
  • — C (S) $2800
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $700.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:        a) A stepladder used by employees to access and egress the trench did not have its side rails extended at least 3 feet above the ground.      No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (S) $700
  • — C (S) $2000
  • — Z (S) $2000

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:      a)  Employees were using a stepladder, to access and egress a trench, without its metal spreaders locked in an open position.      No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339936056.