BOISE, ID —
OSHA Inspection: WESTERN BUILDING MAINTENANCE, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WESTERN BUILDING MAINTENANCE, LLC in 5729 GROVER STREET, BOISE, ID 83709 (NAICS 238160). OSHA activity number 339948085.
Where did this inspection happen?
- Establishment
- WESTERN BUILDING MAINTENANCE, LLC
- Site address
- 5729 GROVER STREET
- City
- BOISE
- State
- ID
- ZIP
- 83709
- Mailing
- 3275 BROWN STREET, BOISE, ID 83714
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.28 A
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $1350.00 Reduced
General-duty citation text
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions: a) On September 8, 2014 employees performed roofing activities using pneumatic nail guns without safety glasses. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (S) $1350
- — Z (S) $2700
1926.1053 B01
- Issued
- Penalty
- Initial $2700.00 · Current $1350.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: a) On September 8, 2014 employees performing roofing activities used an extension ladder for access to the work area. The ladder did not extend three rungs above the eave of the roof. Note) Certification of corrective action is NOT required for this item.
Recent events (2)
- — I (S) $1350
- — Z (S) $2700
1926.1053 B05 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a) On September 8, 2014 employees used an extension ladder that was in a near vertical position for access to the roof work area. Note) Certification of corrective action is NOT required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B13
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On September 8, 2014 employees used the top step of an eight foot A-frame ladder for access to and from the roof. Note) Certification of corrective action is NOT required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A01 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways: a) On September 8, 2014 employees did not recognize and/or acknowledge the hazards of improper placement and use of ladders. Employees used an improperly positioned extension ladder, and employees used the top step of an A-frame ladder. Employees did not take appropriate actions to minimize or eliminate these hazards. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $9000.00 · Current $4500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) On September 8, 2014 employees performed roofing activities on a 5 in 12 pitched roof without a fall protection system in place. Western Building Maintenance, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 699998, citation number 1, item number 1a, and was affirmed as a final order on April 1, 2013, with respect to a workplace located at 6513 Robertson Drive, Boise, ID 83706. Note) Certification and documentation of corrective action ARE required for this item.
Recent events (2)
- — I (R) $4500
- — Z (R) $9000
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in ID
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
CARRILLO CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
SEVY BROTHERS CONSTRUCTION LLC
MERIDIAN, ID—2026-07-17 00:00:00
CBH HOMES
BOISE, ID—2026-07-16 00:00:00
RAYMOND MANAGEMENT COMPANY
Source