MILWAUKEE, WI —
OSHA Inspection: MBD WHEEL AND BRAKE REPAIR AND SERVICES, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MBD WHEEL AND BRAKE REPAIR AND SERVICES, LLC in 2040 WEST CORNELL STREET, MILWAUKEE, WI 53209 (NAICS 336340). OSHA activity number 339961088.
Where did this inspection happen?
- Establishment
- MBD WHEEL AND BRAKE REPAIR AND SERVICES, LLC
- Site address
- 2040 WEST CORNELL STREET
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53209
- Mailing
- 2040 WEST CORNELL STREET, MILWAUKEE, WI 53209
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336340
- Employees
- 27
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.94 A07
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.94(a)(7): Dust was permitted to accumulate on the floor or on ledges outside of an abrasive-blasting enclosure, and dust spills shall be cleaned up promptly. Aisles and walkways were not kept clear of steel shot or similar abrasive which may create a slipping hazard: (a) At the Blast-It-All abrasive blasting cabinet the bad gasket on the door and the holes in the gloves allowed plastic abrasive to escape the blasting cabinet.
Recent events (2)
- — I (O) $0
- — Z (S) $4200
1910.107 G02
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $3150.00 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: (a) The paint booth had a paint overspray accumulation on the inside of the booth on the walls, the floor, and on the electric lift inside the booth.
Recent events (2)
- — I (S) $3150
- — Z (S) $4200
1910.107 C05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(c)(5): Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections: (a) An electric adjustable height table that was not approved for hazardous locations was used inside the paint booth.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(b)(1): Spray booths were not substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying: (a) The paint booth had a combustible plastic board taped over part of the main booth opening.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 D03 III B 2
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life: (a) Employees wearing half-face respirators while painting followed no respirator cartridge change schedule and changed their respirator cartridges every 3 to 4 days.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Employees wearing half-face respirators while blending, painting and abrasive blasting had no medical evaluation conducted prior to being issued the respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.134 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) Employees wearing half-face respirators while blending, painting and abrasive blasting had no fit test conducted prior to being issued the respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): Employee training did not include the details of the hazard communication program developed by the employer, including an explanation of the labeling system and the material safety data sheet, and how employees can obtain and use the appropriate hazard information: (a) There was no training done regarding the GHS topics of new label product identifiers, signal words, hazard statements, and pictograms for chemicals used in the workplace such as, but not limited to, the 3Chem solvent reducer and the Opti-Blast blasting media.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) The outlet that was previously attached to the bench was hanging, unsupported, from the conduit, after the bench was moved.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 336340)
WHITE CITY, OR—2026-02-27 00:00:00
317743422 - BRONSON INVESTMENTS INC
CLOVERDALE, CA—2026-02-03 00:00:00
INDIAN HEAD INDUSTRIES, INC.
FOWLERVILLE, MI—2025-12-30 00:00:00
ZF ACTIVE SAFETY US
ROCKFORD, IL—2025-12-23 00:00:00
ROCKFORD BRAKE MANUFACTURING, INC.
GEORGETOWN, KY—2025-12-16 00:00:00
68659 - YS PRECISION STAMPING INC
More inspections in WI
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15 00:00:00
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15 00:00:00
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15 00:00:00
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15 00:00:00
A. GOMEZ CARPENTRY, INC
Source