MILWAUKEE, WI —
OSHA Inspection: KEIDING, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of KEIDING, INC. in 4545 WEST WOOLWORTH AVENUE, MILWAUKEE, WI 53218 (NAICS 322299). OSHA activity number 340041086.
Where did this inspection happen?
- Establishment
- KEIDING, INC.
- Site address
- 4545 WEST WOOLWORTH AVENUE
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53218
- Mailing
- 4545 WEST WOOLWORTH AVENUE, MILWAUKEE, WI 53218
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322299
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.95 C01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average (TWA) sound level of 85 decibels measured on the A scale, or equivalently, a dose of fifty percent: (a) The employee working around molding lines 2, 4 and 5 was exposed to noise at 86.9 decibels measured on the A scale, exceeding the adjusted time-weighted average of 84.4 decibels measured on the A scale. The sample was taken on December 10, 2014 during a 524 minute sampling period.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.169 B03 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1910.169(b)(3)(i): Compressed air receiver(s) were not equipped with one or more spring-loaded safety valves: (a) All air receivers located in the ceiling over the ovens had no spring-loaded pressure relieving safety valves. (b) One air receiver located along the wall at the south end of line 3 had no spring-loaded pressure relieving safety valve.
Recent events (2)
- — I (S) $600
- — Z (S) $1600
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) The electric control panel door for oven 3 remained open while the oven was in operation.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.146 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: (a) At the pulp tanks there were no signs posted to warn of the danger posed by the permit spaces.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.158 E02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.158(e)(2)(iii): Hose systems were not inspected at least annually to assure that all equipment and hose are in place, available for use, and in serviceable condition: (a) The small hose system mounted on the side of oven 5 was operated by a ball valve mounted at a height of 75 inches above the floor and was not accessible to a person of average height.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at KEIDING, INC.
MILWAUKEE, WI—2026-07-14
KEIDING, INC.
MENOMONEE FALLS, WI—2024-06-28 00:00:00
KEIDING, INC.
MILWAUKEE, WI—2023-04-26 00:00:00
KEIDING, INC.
MILWAUKEE, WI—2021-10-05 00:00:00
KEIDING, INC.
MILWAUKEE, WI—2014-05-27 00:00:00
KEIDING, INC.
View KEIDING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322299)
MILWAUKEE, WI—2026-07-14
KEIDING, INC.
CINCINNATI, OH—2026-06-30
PPG/CINDUS CORPORATION
TRACY, CA—2026-06-29
GEORGIA PACIFIC LLC
CINCINNATI, OH—2026-06-23
PPG/CINDUS CORPORATION
AUBURN, MA—2026-06-16
WORCESTER ENVELOPE COMPANY
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340041086.