MACEDONIA, OH —
OSHA Inspection: SHEFFIELD STEEL PRODUCTS INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SHEFFIELD STEEL PRODUCTS INC in 355 LEDGE RD, MACEDONIA, OH 44056 (NAICS 331110). OSHA activity number 340044247.
Where did this inspection happen?
- Establishment
- SHEFFIELD STEEL PRODUCTS INC
- Site address
- 355 LEDGE RD
- City
- MACEDONIA
- State
- OH
- ZIP
- 44056
- Mailing
- 355 LEDGE RD, MACEDONIA, OH 44056
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331110
- Employees
- 24
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. a) On and before October 28th, 2014 crane operators in the blue slitter bay were permitted to lift 200lbs. 6,000lbs. steel coils with the C style coil grabber which did not have a rated lifting capacity marked on it. b) On and before October 28th, 2014 crane operators in the blue slitter bay were permitted to lift 200lbs. 6,000lbs. steel coils with the green inner diameter coil grabber which did not have a rated lifting capacity marked on it. c) On and before October 28th, 2014 crane operators in the blue slitter bay were permitted to lift 200lbs. 6,000lbs. steel coils with the red inner diameter coil grabber which did not have a rated lifting capacity marked on it.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1910.179 N04 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1910.179(n)(4)(i): The upper limit switch of each hoist was not tried out under no load, at the beginning of each operator's shift. a) On and before, 10/28/2014, at the beginning of each shift at the facility located at 355 ledge Rd., Macedonia, OH 44056, the employer did not ensure that crane operators tested the upper limit switch before using the 25 ton Kranco overhead crane. b) On and before, 10/28/2014, at the beginning of each shift at the facility located at 355 ledge Rd., Macedonia, OH 44056, the employer did not ensure that crane operators tested the upper limit switch before using the 15 ton Zenar overhead crane. c) On and before, 10/28/2014, at the beginning of each shift at the facility located at 355 ledge Rd., Macedonia, OH 44056, the employer did not ensure that crane operators tested the upper limit switch before using the 25 ton ELY overhead crane. d) On and before, 10/28/2014, at the beginning of each shift at the facility located at 355 ledge Rd., Macedonia, OH 44056, the employer did not ensure that crane operators tested the upper limit switch before using the30 ton Detroit overhead crane.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) On or about 10/28/2014, at the facility located at 355 Ledge Rd., Macedonia OH., the employer did not ensure that live electrical wires, at the base of the Loopcoo turn style, were properly insulated, covered, or de-energized. b) On or about 10/28/2014, on the operation deck on the green slitter line, at the facility located at 355 Ledge Rd., Macedonia OH., the employer did not ensure that live electrical wires were de-energized or guarded from protruding out the side and front of a damaged 110 volt electrical outlet box.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1910.179 J02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed. a) On and before, 10/28/2014, at the facility located at 355 ledge Rd., Macedonia, OH 44056, the employer did not ensure that the 25 ton Kranco overhead crane lifting hook was inspected monthly and a written certification of the inspection was generated and documented. b) On and before, 10/28/2014, at the facility located at 355 ledge Rd., Macedonia, OH 44056, the employer did not ensure that the 15 ton Zenar overhead crane lifting hook was inspected monthly and a written certification of the inspection was generated and documented. c) On and before, 10/28/2014, at the facility located at 355 ledge Rd., Macedonia, OH 44056, the employer did not ensure that the 25 ton ELY overhead crane lifting hook was inspected monthly and a written certification of the inspection was generated and documented. D) On and before, 10/28/2014, at the facility located at 355 ledge Rd., Macedonia, OH 44056, the employer did not ensure that the 30 ton Detroit overhead crane lifting hook was inspected monthly and a written certification of the inspection was generated and documented.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 A02 X
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points. On or before 10/28/14, near the #3 blue slitter line at the facility located at 355 Ledge Rd., Macedonia Ohio, the employer did not ensure that the overhead electrical retractable pulley line, which powers the 220 volt coil cart, was protected from damage, pinch points, or other means of exposure damage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SHEFFIELD STEEL PRODUCTS INC
NORTHFIELD, OH—2013-10-08 00:00:00
SHEFFIELD STEEL PRODUCTS INC.
Palatka, FL—1983-03-08
SHEFFIELD STEEL PRODUCTS INC
Palatka, FL—1981-08-14
SHEFFIELD STEEL PRODUCTS INC
Palatka, FL—1981-06-11
SHEFFIELD STEEL PRODUCTS INC
Palatka, FL—1981-05-29
SHEFFIELD STEEL PRODUCTS INC
View SHEFFIELD STEEL PRODUCTS INC's full OSHA safety record →
More inspections in this industry (NAICS 331110)
CANTON, OH—2026-07-09
METALLUS, INC.
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
PITTSBORO, IN—2026-07-06
STEEL DYNAMICS, INC.
PELHAM, AL—2026-06-30
VULCAN STEEL PRODUCTS INC
BLASDELL, NY—2026-06-26
FRONTIER STEEL
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340044247.