OSHA Inspection: MI MAMA'S TORTILLAS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MI MAMA'S TORTILLAS in 828 S. 17TH STREET, OMAHA, NE 68108 (NAICS 311830). OSHA activity number 340116300.

Watch MI Mama'S Tortillas — free Get an email when a new federal OSHA severe-injury report for MI Mama'S Tortillas is published. One employer, no account, unsubscribe in one click.
Establishment
MI MAMA'S TORTILLAS
Site address
828 S. 17TH STREET
City
OMAHA
State
NE
ZIP
68108
Mailing
828 S. 17TH STREET, OMAHA, NE 68108
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311830
Employees
49
Ownership type
A

2 citations on file for this inspection.

1910.147 F03 I

Serious Gravity 10 10 instances 30 exposed
Issued
Abate by
Penalty
Initial $5390.00 · Current $4332.00 Reduced
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew:    Mi Mama's Tortillas 828 S 17th Street, Omaha, NE 68108: The employer is failing to ensure that employees performing maintenance or service to equipment were afforded a level of protection equivalent to a personal lockout device. Employees of Mi Mama's Tortillas are required to perform cleaning activities at least once per week. Maintenance is responsible for de-energizing the equipment and authorized employees place a lock on one of the devices used to de-energize. The authorized employees only are issued one lock and tag and therefore are unable to affectively de-energize the machinery prior performing cleaning.
Recent events (2)
  • — I (S) $4332
  • — Z (S) $5390

1910.305 B01 II

Deleted Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $3273.00 · Current $0.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  In the Maintenance Shop on the BENCO Mill (UNK serial#): the employer is failing to ensure that unused openings on the electrical supply box are effectively closed. During the inspection 2- ½ knockouts were missing from the electrical box on the back side of the mill.