Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,783,325Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DRAHOTA CONSTRUCTION COMPANY

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of DRAHOTA CONSTRUCTION COMPANY in 4055 NORTH ALBION STREET, DENVER, CO 80216 (NAICS 236210). OSHA activity number 340208396.

Watch Drahota Construction Company — free Get an email when a new federal OSHA severe-injury report for Drahota Construction Company is published. One employer, no account, unsubscribe in one click.
Site address
4055 NORTH ALBION STREET
City
DENVER
State
CO
ZIP
80216
Mailing
4700 INNOVATION DR. BLDG C, FORT COLLINS, CO 80527
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.652 A01

Other-than-serious 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $3200.00 · Current $1600.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c):       (a)Drahota Construction Company, Inc. @ 4055 North Albion Street, Denver, CO:  On and before January 22nd, 2015, the controlling employer in charge of the worksite did not ensure each employee working inside excavations were protected from cave-in. The West wall (meter vault) measuring 7-6" deep was excavated in a near vertical configuration. The West wall lacked an adequate protective system, such as sloping, benching, or shield systems.  This condition exposed an employee working for a sub-contractor to hazards associated with cave-in.     (b)Drahota Construction Company, Inc. @ 4055 North Albion Street, Denver, CO:  On and before January 22nd, 2015, the controlling employer did not ensure each employee working inside an excavation (meter vault) was protected from cave-in. The South side excavation wall measuring 7'6" deep excavation lacked appropriate benching contrary to subpart P, Figure B-1.2 for type B soil.
Recent events (2)
  • — I (O) $1600
  • — Z (S) $3200

1926.651 K01

Deleted Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres and or other hazardous conditions:     (a) Drahota Construction Company, Inc., 4055 North Albion Street, Denver, CO:  On and before January 22nd, 2015, the controlling employer did not ensure daily inspections of an excavation measuring approximately 7 -6" in depth were made by a competent person for evidence of a situation that could have resulted in cave-in.  A competent person did not ensure an adequate protective system was utilized prior to entry. The West side of the excavation was sloped at an angle greater than 45 degrees. This condition exposed an employee(s) working for a sub-contractor to potential crushing hazards associated with cave-in.     (b)Drahota Construction Company, Inc., 4055 North Albion Street, Denver, CO: On and before January 22nd, 2015, the controlling employer did not ensure daily inspections of an excavation measuring approximately 7'6" in depth were made by a competent person for evidence of a situation that could have resulted in cave-in.  A competent person did not ensure an adequate protective system was utilized prior to entry. The South side of the excavation was benched at an angle greater than 45 degrees. This condition exposed an employee(s) working for a sub-contractor to potential crushing hazards associated with cave-in.     Abatement Note: "Competent person" means one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View DRAHOTA CONSTRUCTION COMPANY's full OSHA safety record →