MEMPHIS, TN —
OSHA Inspection: FULLEN DOCK & WAREHOUSE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FULLEN DOCK & WAREHOUSE in 382 KLINKE RD, MEMPHIS, TN 38127 (NAICS 488320). OSHA activity number 340425263.
Where did this inspection happen?
- Establishment
- FULLEN DOCK & WAREHOUSE
- Site address
- 382 KLINKE RD
- City
- MEMPHIS
- State
- TN
- ZIP
- 38127
- Mailing
- 382 KLINKE RD, MEMPHIS, TN 38127
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488320
- Employees
- 50
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. a) Maintenance Shop - On or about 2/24/15, employees were exposed slip and trip hazards when the shop was not kept clean and orderly. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1300
- — Z (S) $2100
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least (a) Dock #3 - On or about 2/24/15, employees were exposed to explosion hazards when oxygen and acetylene cylinders were not separated as required. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Maintenance Shop - On or about 2/24/15, employees were exposed to electrical hazards when breaker blank filler plates were not installed in unused openings in the electrical panels. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1918.66 B02
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2275.00 Reduced
General-duty citation text
29 CFR 1918.66(b)(2): Accessible areas within the swing radius of the body of a revolving crane were not physically guarded during operations to prevent employees from being caught between the body of the crane and any fixed structure or between parts of the crane. a) Dock #3 - On or about2/24/15, employees were exposed to struck-by hazards when the swing radius on the Link Belt crane was not guarded. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $2275
- — Z (S) $3500
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Maintenance Shop - On or about 2/24/15, each breaker in the electrical panels had not been labeled indicating the purpose. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Maintenance Shop - On or about 2/24/15, strain relief was not provided on an extension cord. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1915.55 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.55(a)(1): Valve protection caps on gas Welding and cutting cylinders were not in place or secure. a) Dock #3 - On or about 2/24/15, valve caps were not in place on oxygen and acetylene cylinders. b) Maintenance Shop - On or about 2/24/15, valve caps were not in place on oxygen cylinders. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1918.97 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1918.97(d)(2): Stretchers were not kept close to vessels and were not positioned to avoid damage to the stretcher. a) Docks - On or about 2/24/15, the stretcher was not kept close to the vessels being worked. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1918.97 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1918.97(e)(1): The employer did not ensure that there was in the vicinity of each vessel being worked, at least one U.S. Coast Guard approved 30-inch life-ring with no less than 90 feet of line attached. a) Dock #1 - On or about 2/24/15, 90 feet of rope was not attached to the life rings. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at FULLEN DOCK & WAREHOUSE
MEMPHIS, TN—2023-02-21 00:00:00
FULLEN DOCK & WAREHOUSE
MEMPHIS, TN—2022-03-22 00:00:00
FULLEN DOCK & WAREHOUSE
MEMPHIS, TN—2015-02-24 00:00:00
FULLEN DOCK & WAREHOUSE
Memphis, TN—1981-06-10 00:00:00
FULLEN DOCK & WAREHOUSE
View FULLEN DOCK & WAREHOUSE's full OSHA safety record →
More inspections in this industry (NAICS 488320)
MARATHON, FL—2026-07-14 00:00:00
DISCOUNT ROCK & SAND, INC.
RIVIERA BEACH, FL—2026-07-07 00:00:00
PORT CONTRACTORS SOUTHEAST, LLC
JACKSONVILLE, FL—2026-07-01 00:00:00
CROWLEY LINER SERVICES
SEATTLE, WA—2026-06-30 00:00:00
WA317991873 - SSA TERMINALS LLC
TERMINAL ISLAND, CA—2026-06-10 00:00:00
YUSEN TERMINALS LLC
More inspections in TN
FAIRVIEW, TN—2026-07-16 00:00:00
MARVIN PINERA
FAIRVIEW, TN—2026-07-16 00:00:00
DRB GROUP TENNESSEE, LLC
COVINGTON, TN—2026-07-16 00:00:00
CHARMS, LLC
MURFREESBORO, TN—2026-07-16 00:00:00
EUROSTONE LLC
MOUNT JULIET, TN—2026-07-15 00:00:00
SCHNEIDER ELECTRIC USA, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340425263.