Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JF CONSTRUCTION CORP., LTD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JF CONSTRUCTION CORP., LTD in NEW 1 STORY, 4 BEDROOM, 2 BATH, SINGLE FAMILY RESIDENCE DUENAS STREET, MAITE, GU 96910 (NAICS 236115). OSHA activity number 340488683.

Watch JF Construction Corp., LTD — free Get an email when a new federal OSHA severe-injury report for JF Construction Corp., LTD is published. One employer, no account, unsubscribe in one click.
Site address
NEW 1 STORY, 4 BEDROOM, 2 BATH, SINGLE FAMILY RESIDENCE DUENAS STREET
City
MAITE
State
GU
ZIP
96910
Mailing
PO BOX 5332, HAGATNA, GU 96932
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $714.00 Reduced
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors:  On the east side exterior of the project, there was no assured equipment grounding conductor program or ground-fault circuit-interrupter protection when employees used a 110 VAC Makita circular saw, powered through an extension cord, to cut lumber, exposing employees to the hazard of contacting electricity.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1926.405 G02 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief was provided which will prevent pull from being directly transmitted to joints or terminal screws:  On the east side exterior of the project, the outside insulation was not connected to the receptacle on an extension cord that supplied power to a 110 VAC circular saw used to cut lumber, exposing employees to the hazard of contacting electricity.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0