Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAZZEO HOME IMPROVEMENT SPECIALISTS LLC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MAZZEO HOME IMPROVEMENT SPECIALISTS LLC. in RIVER KNOLL BUILDING 27, BALDWINSVILLE, NY 13027 (NAICS 423330). OSHA activity number 340505213.

Watch Mazzeo Home Improvement Specialists LLC. — free Get an email when a new federal OSHA severe-injury report for Mazzeo Home Improvement Specialists LLC. is published. One employer, no account, unsubscribe in one click.
Site address
RIVER KNOLL BUILDING 27
City
BALDWINSVILLE
State
NY
ZIP
13027
Mailing
3161 EAST BAYARD STREET EXTENSION, SENECA FALLS, NY 13148
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423330
Employees
6
Ownership type
A

7 citations on file for this inspection.

1926.451 F07

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:  a) At the jobsite, on the scaffold, on or about 3/31/15:  Employees were working on a pump jack scaffold that was not erected and used under the direction of a competent person.     Abatement certification must be submitted for these items.
Recent events (3)
  • — J (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1926.451 E01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used:  a) At the jobsite, on the scaffold, on or about 3/31/15:  Employees were working on a pump jack scaffold approximately 15 feet from grade where workers were not provided appropriate access to the roof surface that was approximately 3 feet above the working surface of the scaffold.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 G04

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph.  a)  At the jobsite, on  the scaffold, on or about 3/31/15:  Employees were working on a pump jack scaffold approximately 15 feet from grade where a horizontal life line was connected to the scaffold not designed for that equipment.  Abatement certification must be submitted for these items.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 G04 I

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:   a) At the jobsite, on the scaffold, on or about 3/31/15:  Employees were working on a pump jack scaffold approximately 15 feet from grade where the scaffold ends were not protected with guardrails.  Abatement certification must be submitted for these items.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.501 B13

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a)  At the jobsite, on the roof, on or about 3/31/15:  Employees were working on a 5:12 pitch roof with a ground to eave height of approximately 20 feet without fall protection.    Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1926.502 D15 II

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1500.00 Reduced
29 CFR 1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, and not installed under the supervision of a qualified person.    a)  At the jobsite, on the roof, on or about 3/31/15:  2 employees were working on a 5:12 pitch roof with a ground to eave height of approximately 20 feet while being connected to the same anchor point.  A third line was connected to the same anchor point that was not being used when observed.      Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $1500
  • — C (S) $2800
  • — Z (S) $2800

1926.502 D06 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(6)(iii): A snaphook was engaged to a Dee-ring to which another snaphook or other connector is attached and to any objectwhich is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself.  a)  At the jobsite, on the roof, on or about 3/31/15:  2 employees were working on a 5:12 pitch roof with a ground to eave height of approximately 20 feet while being connected to the same anchor point.  A third line was connected to the same anchor point that was not being used when observed.    Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340505213.