Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAXILL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MAXILL, INC. in 500 WEST MAIN STREET, CORTLAND, OH 44410 (NAICS 423450). OSHA activity number 340523539.

Watch Maxill, INC. — free Get an email when a new federal OSHA severe-injury report for Maxill, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MAXILL, INC.
Site address
500 WEST MAIN STREET
City
CORTLAND
State
OH
ZIP
44410
Mailing
500 WEST MAIN STREET, CORTLAND, OH 44410
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423450
Employees
11
Ownership type
A

7 citations on file for this inspection.

1910.333 A

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $2800.00 · Current $1540.00 Reduced
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:    On or about April 7, 2015 at the work site located at 500 W. Main St. Cortland, Ohio 44410 the employer did not ensure Maxill, Inc employees were protected from electrical hazards by creating and implementing a hazardous energy control program. Employees routinely are exposed to electrical shock while replacing receptacles and light fixtures.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $2800

1926.100 A

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $2800.00 · Current $1540.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:       On or about April 7, 2015 during the removal of an overhead crane steel support structure at the work site located at 500 W. main St. Cortland, Ohio 44410. The employer did not ensure employees working under the demolition of a steel support structure were protected from possible danger of head injury from impact, or from falling or flying objects from the employees working directly above.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $2800

1926.350 A10

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1200.00 · Current $660.00 Reduced
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour.     On or about April 7, 2015 during the removal of an overhead crane steel support structure at the work site located at 500 W. Main St. Cortland, Ohio 44410 the employer did not ensure that the oxygen and acetylene cylinders that were not in continuous use were stored properly.
Recent events (2)
  • — I (S) $660
  • — Z (S) $1200

1926.602 C01 II

Serious Gravity 10 2 instances 3 exposed
Issued
Penalty
Initial $2800.00 · Current $1540.00 Reduced
29 CFR 1926.602(c)(1)(ii): Modifications or additions affecting the safe operation of the equipment were  made without the manufacturer's written approval:     On or about April 7, 2015 during the removal of an overhead crane steel support structure at the work site located at 500 W. Main St. Cortland, Ohio 44410 employees utilized power industrial vehicles with non-approved wooden boxes to gain boom height which supported the steel beam as it was being cut.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $2800

1926.850 A

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $2800.00 · Current $1540.00 Reduced
29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the conditions of the framing floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations.     On or about April 7, 2015 at the work site located at 500 W. Main St. Cortland, Ohio 44410. The employer directed the start of demolition operations of an overhead crane steel support structure without an engineering survey.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $2800

1926.858 D

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1540.00 Reduced
29 CFR 1926.858(d): Any structural member being dismembered shall not be overstressed.     On or about April 7, 2015 during the removal of an overhead crane steel support structure at the work site located at 500 W. Main St. Cortland, Ohio 44410 the employer did not ensure that the steel structure being dismembered was not overstressed by which an employee was almost struck by a flexing steel beam as it was being cut for removal.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $2800

1910.1200 F08

Other-than-serious 1 instance 11 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(8): 29 CFR 1910.1200(f)(8): The employer did not label portable containers into which hazardous chemicals were transferred.     On or about April 7, 2015 at the work site located at 500 W. Main St. Cortland, Ohio 44410 the employer did not ensure portable containers into which hazardous chemicals were transferred were labeled nor intended for immediate use. Multiple containers were observed without labels. The containers of chemicals were for the cleaning of different types of surfaces by the cleaning crew whom had not been on site for more than a day.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

LIPPERT

PROVIA

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340523539.