FORT DEFIANCE, AZ —
OSHA Inspection: BIE-NAVAJO DISTRICT
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of BIE-NAVAJO DISTRICT in ARIZONA NAVAJO SOUTH PAQUOLTE DR., BIE BLDG 148, FORT DEFIANCE, AZ 86504 (NAICS 238220). OSHA activity number 340560150.
Where did this inspection happen?
- Establishment
- BIE-NAVAJO DISTRICT
- Site address
- ARIZONA NAVAJO SOUTH PAQUOLTE DR., BIE BLDG 148
- City
- FORT DEFIANCE
- State
- AZ
- ZIP
- 86504
- Mailing
- P.O. BOX 1449, WINDOW ROCK, AZ 86515
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 9
- Ownership type
- D
Citations
8 citations on file for this inspection.
1910.146 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: a) AZ Navajo South, BIE Facility Management, Fort Defiance, AZ: On or about April 16, 2015 and at times prior thereto, employees entered tunnels to repair steam and water pipe leaks. The tunnels were not evaluated to determine if they were permit-required confined spaces.
Recent events (2)
- — Z $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) AZ Navajo South, BIE Facility Management, Fort Defiance, AZ: On or about April 16, 2015 and at times prior thereto, operators of the Clark CMP 70D forklift were not evaluated regarding their competency to operate the forklift safely.
Recent events (2)
- — Z $0
- — Z (S) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Bldg 148, Business Tech's Office, Fort Defiance, AZ: On or about April 16, 2015 and at times prior thereto, a relocatable power tap (RPT) was daisy chained to another RPT to power the computer system. Employees were exposed to a fire hazard. b) Bldg 148, Conference Room, Fort Defiance, AZ: On or about April 16, 2015 and at times prior thereto, a relocatable power tap was used to power a microwave and a refrigerator which are high current draw appliances. Employees were exposed to a fire hazard.
Recent events (1)
- — Z (S) $0
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) BIE Facility Management-Bldg 148, Copier Room, Fort Defiance, AZ: On or about April 16, 2015 and at times prior thereto, the faceplate was missing on the outlet that powered the HP laser jet printer. Employees were exposed to an electrical shock hazard.
Recent events (1)
- — Z (S) $0
1926.1101 F01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1101(f)(1)(i): Where exposure monitoring was required under 29 CFR 1926.1101, the employer did not perform monitoring to determine accurately the airborne concentrations of asbestos to which employees were or potentially were exposed: a) AZ Navajo South, BIE Facility Management, Fort Defiance, AZ: On or about April 16, 2015 and at times prior thereto, employee exposure monitoring was not performed for employees who entered tunnels to repair steam and water pipe leaks. The pipes were covered with asbestos thermal system insulation (TSI) and the insulation was friable due to damage and deterioration.
Recent events (2)
- — Z $0
- — Z (S) $0
1926.1101 G01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1101(g)(1)(i): The employer did not use vacuum cleaners equipped with high efficiency particulate air (HEPA) filters to collect all debris in operations covered by 29 CFR 1926.1101, regardless of the levels of exposure: a) AZ Navajo South, BIE Facility Management, Fort Defiance, AZ: On or about April 16, 2015 and at times prior thereto, employees entered tunnels to repair steam and water pipe leaks. The tunnel floor was covered with asbestos thermal system insulation (TSI ) due to damage and deterioration to the TSI.
Recent events (2)
- — Z $0
- — Z (S) $0
1926.1101 H02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1101(h)(2)(i): The employer failed to implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) [except (d)(1)(iii)], and (f) through (m), which covers each employee required by 29 CFR 1926.1101 to use a respirator: a) AZ Navajo South, BIE Facility Management, Fort Defiance, AZ: On or about April 16, 2015 and at times prior thereto, employees donned respirators and entered tunnels to repair steam and water pipe leaks. The asbestos thermal system insulation (TSI) covering the pipe was friable due to damage and deterioration. Annual medical evaluations to determine the employee's ability to use a respirator were not provided. Also, annual respirator fit tests were not provided.
Recent events (2)
- — Z $0
- — Z (S) $0
1904.30 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1904.30(a): The employer did not maintain a separate OSHA 300 Log for each establishment that was expected to be in operation for one year or longer. a) AZ Navajo South, BIE Facility Management, Fort Defiance, AZ: On or about April 16, 2015 and at times prior thereto, the agency did not maintain a separate OSHA 300 Log for the Fort Defiance, AZ location.
Recent events (1)
- — Z (O) $0
More inspections at BIE-NAVAJO DISTRICT
FORT DEFIANCE, AZ—2016-02-11 00:00:00
BIE-NAVAJO DISTRICT
FORT DEFIANCE, AZ—2016-02-11 00:00:00
BIE-NAVAJO DISTRICT
FORT DEFIANCE, AZ—2015-04-16 00:00:00
BIE-NAVAJO DISTRICT
FORT DEFIANCE, AZ—2015-04-16 00:00:00
BIE-NAVAJO DISTRICT
FORT DEFIANCE, AZ—2015-04-15 00:00:00
BIE-NAVAJO DISTRICT
View BIE-NAVAJO DISTRICT's full OSHA safety record →
More inspections in this industry (NAICS 238220)
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
RIO RANCHO, NM—2026-07-15
PROFESSIONAL STUCCO & SERVICE INC.
BROOKLYN, NY—2026-07-15
DILIGENT AC LLC
PARKVILLE, MD—2026-07-15
AMERICAN AUTOMATIC SPRINKLER COMPANY, INC.
SACRAMENTO, CA—2026-07-15
J.R. PIERCE PLUMBING CO., INC. OF SACRAMENTO
More inspections in AZ
CHANDLER, AZ—2026-07-16
SUN STATE BUILDERS
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
CAMP VERDE, AZ—2026-07-14
CLIFF CASTLE CASINO & HOTEL
CAMP VERDE, AZ—2026-07-14
CLIFF CASTLE CASINO & HOTEL
TUCSON, AZ—2026-07-10
CPX2026XJL680X0074 - JANC EXCAVATING AND CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340560150.