PISCATAWAY, NJ —
OSHA Inspection: AMBROSIA FRAGRANCE, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AMBROSIA FRAGRANCE, LLC in 7 TURNER PLACE, PISCATAWAY, NJ 08855 (NAICS 325620). OSHA activity number 340584663.
Where did this inspection happen?
- Establishment
- AMBROSIA FRAGRANCE, LLC
- Site address
- 7 TURNER PLACE
- City
- PISCATAWAY
- State
- NJ
- ZIP
- 08855
- Mailing
- 7 TURNER PLACE, PISCATAWAY, NJ 08855
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325620
- Employees
- 42
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.23 A08
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.23(a)(8): Floor hole(s), into which persons could accidentally walk, were not guarded by floor hole covers of standard strength and construction: a/ Ambrosia Fragrance/Piscataway NJ Site: Mixing/Store Room. Floor openings used for drainage when product spills and process tanks are washed down and drained were not adequately covered to prevent employees from accidentally tripping and falling. Drain covers (metal grates) provided were damaged and/or missing sections leaving openings where employees could accidentally walk into them and/or trip over the damaged grates. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $2800
- — C (S) $2800
- — Z (S) $2800
1910.23 C03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment shall be guarded: a/ Ambrosia Fragrance/Piscataway NJ Site: Former Compactor Dock/Propane Storage Area. The space between the dock and the landing (approx. 18 inches) where the compactor was formerly located was not covered to prevent employee(s) from accidently stepping into the opening. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $2800
- — C (S) $2800
- — Z (S) $2800
1910.24 B
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated travel regularly, daily, or at each shift: a/ Ambrosia Fragrance/Piscataway NJ Site: Former Compactor Dock/Propane Storage Area. Stairs were not provided to reach the ground level. A wooden plank was used to access the ground from the dock level. Fixed stairs and/or other approved means were not provided to prevent employees from falling. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $2800
- — C (S) $2800
- — Z (S) $2800
1910.106 E02 IV D
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessel(s), container(s), or portable tank(s) within a building through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tank by gravity through an approved self-closing valve: a/ Ambrosia Fragrance/Piscataway NJ Site: Mixing/Store Room. Safety can(s) were not provided and used in all areas to dispense and store Category 2 flammable liquid(s) into secondary containers including but not limited to Denatured Ethyl Alcohol (flash point ranging from 55.4 to 60.8 degrees F and boiling point at 173.12 F. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $2500
- — C (S) $3500
- — Z (S) $3500
1910.106 E06 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat: a/ Ambrosia Fragrance/Piscataway NJ Site: Mixing/Store Room. Means were not provided and/or used to prevent vapors from igniting where open containers larger than 5 gal. capacity were used to carry Category 2 flammable liquid(s) to be used in the batch making process. Flammable liquids including but not limited to Denatured Ethyl Alcohol (flash point ranging from 55.4 to 60.8 degrees F and boiling point of 173.12 F. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $0
- — C (S) $3500
- — Z (S) $3500
1910.106 E06 II
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 2 flammable liquids were dispensed into containers without the nozzle and container electrically interconnected: a/ Ambrosia Fragrance/Piscataway NJ Site: Mixing/Store Room. Bonding and grounding is not always used when Category 2 flammable liquid(s) are being dispensed. Denatured Ethyl Alcohol (flash point ranging from 55.4 to 60.8 degrees F and boiling point of 173.12 F) is dispensed through a closed piping system into secondary metal and plastic containers. Means to prevent static sources of ignition were not provided. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $0
- — C (S) $3500
- — Z (S) $3500
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h): a/ Ambrosia Fragrance/Piscataway NJ Site: Production Areas. All hard-wired machinery/equipment and all cord/plug connected equipment where the employee does not have exclusive control over the cord/plug at all times when providing maintenance/service. The lockout program provided did not include but not limited to the following: 1/ the program was not documented and tailored to the site specific equipment to be worked on 2/ there were no specific steps documented to de-energize the equipment 3/ means to control the use and identity of locking devices 4/ designated personnel involved in the program, etc. Equipment include but not limited to: Filling Machines, Packaging Machines, etc. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $2500
- — C (S) $3500
- — Z (S) $3500
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): The employer did not ensure that an evaluation of each powered industrial truck operator's performance was conducted at least once every three years: a/ Ambrosia Fragrance/Piscataway NJ/Site: Production/Warehouse. Forklift operators who had been previously trained had not been provided an evaluation of that training in the last three years. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $2500
- — C (S) $3500
- — Z (S) $3500
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) with defect(s) or in any way unsafe had not been withdrawn from service until restored to safe operating condition(s): a/ Ambrosia Fragrance/Piscataway NJ Site: Warehouse. Mitsubishi Propane Powered Forklift Truck/Standard Sit-Down Type, the right bracket used to secure the Propane tank into place was broken. The Forklift truck had not been tagged and placed out of service until repaired. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $2500
- — C (S) $3500
- — Z (S) $3500
1910.212 B
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a/ Ambrosia Fragrance/Piscataway NJ Site: Maintenance Shop. Central Machinery 8 Inch Drill Press Bench Type was not secured to prevent moving during operation. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $2800
- — C (S) $2800
- — Z (S) $2800
1910.303 G01 II
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space provided about electrical equipment rated 600 volts, nominal, or less was used for storage: a/ Ambrosia Fragrance/Piscataway NJ Site: Production/Warehouse. Electrical breaker and panel boxes rated 480 volts/3 phases were blocked by empty cardboard boxes and boxes containing product. A minimum 3 ft. of working space was not maintained in front if electrical boxes. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $2500
- — C (S) $3500
- — Z (S) $3500
1910.333 B02 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $3500.00
General-duty citation text
29 CFR 1910.333(b)(2)(i): The employer did not make a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 available for inspection by employees: a/ Ambrosia Fragrance/Piscataway NJ Site: Production/Maintenance Areas. Where employee(s) are required to perform limited (standard and live) electrical maintenance on machinery/equipment, OSHA regulation 1910.333(b) and/or an equivalent was not made available to them. Employee performs electrical maintenance/testing on machinery/equipment rated 208 Volts/3 phases using a "Fluke" meter/tester. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $3500
- — C (S) $3500
- — Z (S) $3500
1910.335 A01 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: a/ Ambrosia Fragrance/Piscataway NJ Site: Production/ Maintenance Areas. Production/Maintenance Areas: Where employees are required (on a limited basis) to perform live electrical testing and/or trouble-shooting on machinery/equipment, protectors including but not limited to approved electrical gloves (ANSI rated 00 or 01 - minimum 500 volts) etc. were not provided for each electrical worker. Observed on/or about 04/21/2015.
Recent events (3)
- — R (S) $0
- — C (S) $3500
- — Z (S) $3500
More inspections at AMBROSIA FRAGRANCE, LLC
PISCATAWAY, NJ—2015-04-08 00:00:00
AMBROSIA FRAGRANCE, LLC
View AMBROSIA FRAGRANCE, LLC's full OSHA safety record →
More inspections in this industry (NAICS 325620)
ROCHESTER, NY—2026-07-01
ROLEN TECHNOLOGIES NORTH AMERICA, LLC
CLEVELAND, OH—2026-06-23
U.S. COTTON LLC
WEARE, NH—2026-06-08
TRI-K INDUSTRIES
BLUE ISLAND, IL—2026-05-28
RNA CORPORATION
SALEM, MA—2026-05-07
TROPICAL PRODUCTS INC
More inspections in NJ
FREEHOLD, NJ—2026-07-10
MARIO & SONS CONSTRUCTION GROUP, LLC
FREEHOLD, NJ—2026-07-10
VACCA ROOFING
FREEHOLD, NJ—2026-07-10
SPECTRA PAINTING, INC
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
FREEHOLD, NJ—2026-07-10
GTN CONSTRUCTION INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340584663.