MIRAMAR, FL —
OSHA Inspection: L B CONSTRUCTION OF SOUTH FLORIDA, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of L B CONSTRUCTION OF SOUTH FLORIDA, INC. in 2700 UNIVERSITY DRIVE, MIRAMAR, FL 33023 (NAICS 236220). OSHA activity number 340598911.
Where did this inspection happen?
- Establishment
- L B CONSTRUCTION OF SOUTH FLORIDA, INC.
- Site address
- 2700 UNIVERSITY DRIVE
- City
- MIRAMAR
- State
- FL
- ZIP
- 33023
- Mailing
- 1990 NE 149 STREET, NORTH MIAMI, FL 33181
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 11
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Penalty
- Initial $4900.00 · Current $4900.00
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 04/30, 2015, at the above addressed worksite, employees installing blocks at the roof level of a building were exposed to a fall hazard of approximately 20-feet.
Recent events (1)
- — Z (S) $4900
1926.701 B
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $2400.00
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: On or about 04/30/2015, at the above addressed worksite, employees installing concrete blocks at the edge of a building were exposed to laceration and impalement hazards from uncapped rebar rods.
Recent events (1)
- — Z (S) $2400
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about 04/30/2015, at the above addressed worksite, employees installing concrete blocks at the edge of a building were using an extension ladder that did not extend at least 3-feet above the edge of the roof exposing them to a fall hazard of approximately 20-feet.
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 236220)
ROCHESTER, NH—2026-07-17 00:00:00
STAR CONSTRUCTION SVS INC
WHITESTOWN, IN—2026-07-17 00:00:00
CENTRAL WELDING INC
MOUNTAIN LAKES, NJ—2026-07-17 00:00:00
JOHN CARUSO BUILDERS LLC
FAIRFAX, VA—2026-07-17 00:00:00
RYCON CONSTRUCTION, INC.
SHAWNEE, KS—2026-07-16 00:00:00
BRATTON BROTHERS CONTRACTING INC
More inspections in FL
DELAND, FL—2026-07-16 00:00:00
BALL FABRICS
GAINESVILLE, FL—2026-07-16 00:00:00
WACKY SAUCES LLC
FORT WALTON BEACH, FL—2026-07-16 00:00:00
WASTE MANAGEMENT, INC. OF FLORIDA
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
PALM COAST, FL—2026-07-16 00:00:00
J & J TREE EXPERTS, INC.
Source