CHICAGO, IL —
OSHA Inspection: LOCAL ROOFING CO., INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of LOCAL ROOFING CO., INC. in 4245 N KNOX AVE, CHICAGO, IL 60641 (NAICS 238160). OSHA activity number 340617257.
Where did this inspection happen?
- Establishment
- LOCAL ROOFING CO., INC.
- Site address
- 4245 N KNOX AVE
- City
- CHICAGO
- State
- IL
- ZIP
- 60641
- Mailing
- 1394 ST. PAUL AVE., GURNEE, IL 60031
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 59
- Ownership type
- A
Citations
10 citations on file for this inspection.
1926.1101 E01
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $0.00 Reduced
9020
General-duty citation text
29 CFR 1926.1101(e)(1): Operations covered by this standard, other than Class I, II, and III work, in which airborne concentrations of asbestos exceeded, or where there was a reasonable possibility they could exceed the permissible exposure limit (PEL), were not conducted within a regulated area: a) On or about April 20, 2015, while performing roof replacement work, employees of Local Roofing Co., Inc. cut through asbestos containing material with axes and a power saw and performed cleanup work. This work was not conducted within a regulated area. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $5390
1926.1101 G11 I
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $7000.00
9020
General-duty citation text
29 CFR 1926.1101(g)(11)(i): Before work began and as needed during the job, a competent person who was capable of identifying asbestos hazards in the workplace and selecting the appropriate control strategy for asbestos exposure and who had the authority to take prompt corrective measures to eliminate such hazards did not conduct an inspection of the worksite and did not determine that the roofing material was intact and was likely to remain intact: a) On or about April 20, 2015, Local Roofing Co., Inc. did not ensure that an appropriate control strategy for asbestos exposure was completed by a competent person immediately before or at the initiation of operations involving cutting and cleanup of asbestos containing material. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $7000
- — Z (S) $5390
1926.1101 G03 III
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $0.00 Reduced
9020
General-duty citation text
29 CFR 1926.1101(g)(3)(iii): Dust and debris containing asbestos containing material and presumed asbestos containing material were dry swept, shoveled or removed by other dry clean-up methods: a) On or about April 20, 2015, employees of Local Roofing Co., Inc. utilized dry cleanup methods such as sweeping and shoveling when cleaning up asbestos containing material after it had been cut. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $5390
1926.1101 G09 I
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $0.00 Reduced
9020
General-duty citation text
29 CFR 1926.1101(g)(9)(i): Class III asbestos work was not performed using wet methods: a) On or about April 20, 2015, Local Roofing Co., Inc., did not require its employees to use engineering and work practice controls such as wet methods or wetting agents when cutting and cleaning up asbestos containing material and presumed asbestos containing material. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $5390
1926.1101 G09 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9020
General-duty citation text
29 CFR 1926.1101(g)(9)(ii): Class III asbestos work was not performed using local exhaust ventilation to the extent feasible: a) On or about April 20, 2015, Local Roofing Co., Inc., did not require its employees to use engineering controls such as local exhaust ventilation when cutting and cleaning up asbestos containing material and presumed asbestos containing material. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1101 H03 III A
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $0.00 Reduced
9020
General-duty citation text
29 CFR 1926.1101(h)(3)(iii)(A): The employer did not provide a half-mask air-purifying respirator, other than a disposable respirator, equipped with high-efficiency filters, whenever the employee(s) performed Class II and III asbestos jobs where no negative exposure assessment was available: a) On or about April 20, 2015, the employer did not select and provide the appropriate respirators for use against asbestos fibers. The employees were provided filtering facepiece respirators to be used when cutting and cleaning up asbestos containing material. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $5390
1926.1101 I01
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $0.00 Reduced
9020
General-duty citation text
29 CFR 1926.1101(i)(1): The employer did not provide and require the use of protective clothing, such as coveralls or similar whole-body clothing, head coverings, gloves, and foot coverings for each employee exposed to airborne concentrations of asbestos for which a required negative exposure assessment was not produced: a) On or about April 20, 2015, Local Roofing Co., Inc. did not provide and require the use of protective clothing when cutting and cleaning up asbestos containing material. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $5390
1926.1101 J02
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $0.00 Reduced
9020
General-duty citation text
29 CFR 1926.1101(j)(2): The hygiene facilities and practices listed in sections (i) through (v) of this paragraph were not followed for employees performing Class I work involving less than 25 linear or 10 square feet of TSI or surfacing ACM and PACM, and for Class II and Class III asbestos work operations where exposures exceed a PEL or where there is no negative exposure assessment produced before the operation: a) On or about April 20, 2015, Local Roofing Co., Inc. did not provide decontamination facilities required by 29 CFR 1926.1101(j)(2) for employees performing cutting and cleanup of asbestos containing material when no negative exposure assessment had been conducted. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $5390
1926.1101 K03 I
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $7000.00
9020
General-duty citation text
29 CFR 1926.1101(k)(3)(i): Before work in areas containing ACM or PACM is begun; employer(s) did not identify the presence, location and quantity of ACM and/or PACM therein pursuant to paragraph (k)(1) of this section. a) On or about April, 20 2015, Local Roofing Co., Inc. did not identify the presence, location, and quantity of asbestos containing material and/or presumed asbestos containing material in the work area before work involving asbestos containing material and/or presumed asbestos containing material was initiated. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $7000
- — Z (S) $5390
1926.1101 G11 II
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $7000.00
9020
General-duty citation text
29 CFR 1926.1101(g)(11)(ii): All employees performing work covered by 29 CFR 1926.1101(g)(11) were not trained in a training program that meet the requirements of 29 CFR 1926.1101(k)(9)(viii): a) On or about April 20, 2015, Local Roofing Co., Inc. did not provide employees with asbestos training that meet the requirements of 29 CFR 1926.1101(k)(9)(viii). In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $7000
- — Z (S) $5390
More inspections at LOCAL ROOFING CO., INC.
WHEELING, IL—2019-04-01 00:00:00
LOCAL ROOFING CO., INC.
WHEELING, IL—2019-04-01 00:00:00
LOCAL ROOFING CO., INC.
GURNEE, IL—2018-08-31 00:00:00
LOCAL ROOFING CO., INC.
GURNEE, IL—2018-08-30 00:00:00
LOCAL ROOFING CO., INC.
SAINT CHARLES, IL—2016-06-07 00:00:00
LOCAL ROOFING CO., INC.
View LOCAL ROOFING CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340617257.