BLOOMER, WI —
OSHA Inspection: BLOOMER MACHINE & FABRICATION INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BLOOMER MACHINE & FABRICATION INC. in 7697 HWY 64, BLOOMER, WI 54724 (NAICS 332710). OSHA activity number 340628866.
Where did this inspection happen?
- Establishment
- BLOOMER MACHINE & FABRICATION INC.
- Site address
- 7697 HWY 64
- City
- BLOOMER
- State
- WI
- ZIP
- 54724
- Mailing
- 7697 HWY 64, BLOOMER, WI 54724
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 14
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Throughout the facility; The employer did not provide employees with specific procedures for the control of hazardous energy, and the means to enforce compliance unique to each machine for use during setup, service and maintenance on equipment such as but not limited to mills, lathes, presses and plasma arc table.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) Throughout facility; The employer did not provide adequate training of the hazardous energy control program prior to performing setup, service and maintenance on equipment such as but not limited to mills, lathes, presses and plasma arc table.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Throughout facility; Employees did not affix lock-out/tag-out device to the machines during setup, servicing and maintenance on equipment such as but not limited to mills, lathes, presses and plasma arc table.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section: (a) Throughout the facility; Adequate periodic inspections of the cranes were not being performed. (i) Mill and Lathing department; A fabricated gantry crane dedicated to the Haas VF-4 Mill, used to lift large parts into the mill when needed intermittently did not have adequate periodic inspections performed. (ii) Fabrication department; A 2 ton Contrx jib crane being used for placing large metal sheets into Hypertherm plasma cutting system when needed intermittently did not have adequate periodic inspections performed.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.179 K01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(k)(1)(i): Prior to initial use, new or altered crane(s) were not operationally tested to insure compliance with 29 CFR 1910.179: (a) Mill and Lathing department; A fabricated gantry crane, dedicated to the Haas VF-4 Mill, did not have documentation of operational testing prior to initial use available upon request.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 K02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(k)(2): Rated load test reports were not placed on file where they were readily available to appointed personnel: (a) Throughout the facility; The cranes did not have rated load test reports on file where they were readily available. (i) Mill and Lathing department; A fabricated gantry crane, dedicated to the Haas VF-4 Mill used to lift large parts into the mill when needed intermittently did not have rated load test reports on file (ii) Fabrication department; A 2 ton Contrx jib crane being used for placing large metal sheets into Hypertherm plasma cutting system when needed intermittently did not have rated load test reports on file .
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 M01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(m)(1): Thorough monthly inspections of rope conditions, with written, dated and signed reports, were not performed on the running ropes: (a) Throughout the facility; The employer was not documenting required monthly wire rope inspections. (i) Mill and Lathing department; A fabricated gantry crane system dedicated to the Haas VF-4 Mill used to lift large parts into the mill, when needed intermittently, did not have adequate monthly inspections of the wire rope performed. (ii) Fabrication department; A 2 ton Contrx jib crane being used for placing large metal sheets into Hypertherm plasma cutting system when needed intermittently, did not have adequate monthly inspections of the wire rope performed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or in an acetylene generator compartment: (a) Fabrication area; Oxygen cylinders were stored near reserve stocks of carbide and acetylene or other fuel-gas cylinders such as but not limited to propylene.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.254 D09 III
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.254(d)(9)(iii): Joining lengths of work and electrode cables by the use of connecting means did not have insulation adequate for the service conditions: (a) Fabrication area; The electrode cable on the Miller Deltaweld 451, metal inert gas (MIG) welder was spliced together using wire nuts and electrical tape which does not adequately insulate the electrode cable.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.303 G01 II
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) Mill and Lathing area; The required 36 inches in front of enclosed electric equipment rated 600 volts, nominal, or less was used for storage.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) Fabrication area; A 240 volt, three phase outlet did not have a faceplate and was not guarded against accidental contact.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01 I
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1440.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet: (a) Bloomer Machine and Fabrication, Inc.; The written hazard communication program did not include a list of the hazardous chemicals such as but not limited to; coolant for plasma cutter, oxygen, propylene, paints and lubricant for mills and lathes.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Bloomer Machine and Fabrication, Inc.; The employees were not provided effective information and training on chemicals such as but not limited to; coolant for plasma cutter, oxygen, propylene, paints and lubricant for mills and lathes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at BLOOMER MACHINE & FABRICATION INC.
BLOOMER, WI—2025-02-04
BLOOMER MACHINE & FABRICATION, INC.
BLOOMER, WI—2022-11-30 00:00:00
BLOOMER MACHINE & FABRICATION, INC.
BLOOMER, WI—2019-03-26 00:00:00
BLOOMER MACHINE & FABRICATION, INC.
BLOOMER, WI—2019-02-28 00:00:00
BLOOMER MACHINE & FABRICATION, INC.
View BLOOMER MACHINE & FABRICATION INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
WIXOM, MI—2026-07-16
MANSON MANUFACTURING LLC DBA TOMCO MANUFACTURING
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLARKLAKE, MI—2026-07-15
CLARKLAKE MACHINE INC
MUSKEGON HEIGHTS, MI—2026-07-15
L. THOMPSON COMPANY LLC DBA TOTAL QUALITY MACHINING
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340628866.