CHICAGO, IL —
OSHA Inspection: YAM CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of YAM CONSTRUCTION, INC. in 1479 W. SUPERIOR AVENUE, CHICAGO, IL 60643 (NAICS 238160). OSHA activity number 340702604.
Where did this inspection happen?
- Establishment
- YAM CONSTRUCTION, INC.
- Site address
- 1479 W. SUPERIOR AVENUE
- City
- CHICAGO
- State
- IL
- ZIP
- 60643
- Mailing
- 2705 S. SAWYER AVENUE, CHICAGO, IL 60623
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about June 11, 2015 - at a jobsite located at 1479 W. Superior Ave., Chicago, IL. - employees performing tuckpointing on a flat roof were not protected from fall screated by the presence of unprotected sides/edges, thereby exposing the employees to fall hazards of approximately thirty (30) feet.
Recent events (3)
- — F (S) $600
- — C (S) $2800
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support: a) On or about June 11, 2015 - at a jobsite located at 1479 W. Superior Ave., Chicago, IL. - employees performing tuck pointing were using a portable ladder to access the roof that did not extend three (3) feet above the upper landing surfaces, thereby exposing the employees to fall hazards of approximately ten (10) feet.
Recent events (3)
- — F (S) $600
- — C (S) $1200
- — Z (S) $1200
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16 00:00:00
MARVIN PINERA
CARSON CITY, NV—2026-07-16 00:00:00
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16 00:00:00
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16 00:00:00
CARLOS CHE
BALTIMORE, MD—2026-07-16 00:00:00
VAL CONSTRUCTION INC
More inspections in IL
DEERFIELD, IL—2026-07-16 00:00:00
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16 00:00:00
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16 00:00:00
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16 00:00:00
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16 00:00:00
B & M PLASTIC INC.
Source