OSHA Inspection: STURGEON ELECTRIC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STURGEON ELECTRIC in 8300 W. 38TH AVENUE, WHEAT RIDGE, CO 80033 (NAICS 238210). OSHA activity number 340742469.

Watch Sturgeon Electric — free Get an email when a new federal OSHA severe-injury report for Sturgeon Electric is published. One employer, no account, unsubscribe in one click.
Establishment
STURGEON ELECTRIC
Site address
8300 W. 38TH AVENUE
City
WHEAT RIDGE
State
CO
ZIP
80033
Mailing
12150 E. 112TH AVENUE, HENDERSON, CO 80640
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $12471.00
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    (a) On or about June 25, 2015, the employer permitted employee(s) to work in close proximity of an energized Motor Control Center 277/480 volt circuit which exposed the employee(s) to shock, electrocution and/or injuries from arc flash hazards.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $12471
  • — C (S) $7000
  • — Z (S) $7000

1926.416 A03

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit:  (a) On or about June 25, 2015, the employer did not ascertain by inquiry, direct observation, or by instruments as to the exact location of the energized part(s) in the Motor Control Center (DP3A panel).  The employee(s) were exposed to shock, electrocution and/or injuries from arc flash hazards.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1926.21 B02

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury   (a) On or about June 25, 2015, the employer did not ensure employees were protected from arc flash hazards. A hazard assessment was not effectively performed and communicated to employees in determining all of the electrical hazards to which the workers could have been exposed.  This includes shock hazard analysis, arc flash hazard analysis and selection of appropriate personnel protective equipment that is suitable for the conditions and magnitude of the electrical hazards to which the workers could be exposed.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.95 A

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact.  1) On or about June 25, 2015, the employer exposed employees to arc flash hazards while working on the Motor Control Center (DP3A panel) within the arc flash boundary without appropriate personal protective equipment.  The employee(s) were exposed to shock, electrocution and/or injuries from arc flash hazards due to removing wires out of the Motor Control Center while within the close proximity of a live 277/480 volt circuit.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

View STURGEON ELECTRIC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340742469.