Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,783,325Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HYQUIP, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HYQUIP, LLC in 4665 N. 124TH ST, BUTLER, WI 53007 (NAICS 332912). OSHA activity number 340752724.

Watch Hyquip, LLC — free Get an email when a new federal OSHA severe-injury report for Hyquip, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
HYQUIP, LLC
Site address
4665 N. 124TH ST
City
BUTLER
State
WI
ZIP
53007
Mailing
4665 N. 124TH ST, BUTLER, WI 53007
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332912
Employees
17
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Employees were not protected from flying metal chips during the operating cycle of the two Eaton Aeroquip ProCrimp 1380 Crimp Machines.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.1200 F05 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  (a) A bottle of hydraulic oil in the crimp machine area did not contain proper labels to identify the contents nor the hazards associated with the contents.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) Employees who fill 5 gallon containers out of a 120 gallon container of Corey Oil Premium Anti-Wear "HD" Hydraulic Oil -AW32 Standard have not received training on the product and where the Safety Data Sheets are located for the information on the associated hazards of that product.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0