VANDERGRIFT, PA —
OSHA Inspection: ALLEGHENY LUDLUM, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ALLEGHENY LUDLUM, LLC in 130 LINCOLN AVENUE, VANDERGRIFT, PA 15690 (NAICS 331221). OSHA activity number 340764976.
Where did this inspection happen?
- Establishment
- ALLEGHENY LUDLUM, LLC
- Site address
- 130 LINCOLN AVENUE
- City
- VANDERGRIFT
- State
- PA
- ZIP
- 15690
- Mailing
- 130 LINCOLN AVENUE, VANDERGRIFT, PA 15690
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331221
- Employees
- 203
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.305 E01
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $3750.00 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures: a) Compressor room, back side of 91 Line, 130 Lincoln Avenue, Vandergrift, PA 15690: On or about June 18, 2015, a roof drain located near the back of a 2300 Volt panel (on the opposite side of the wall) leaks water during heavy rain storms. The water pools in the compressor room which houses a 2300 volt panel and other energized equipment. Employees working in the compressor room, including those required to fill out compressor log sheets, are exposed to the hazards of electric shock and electrocution during periods of heavy rain. b) F-Bus substation, back side of 91 line, 130 Lincoln Avenue, Vandergrift, PA 15690: On or about June 18, 2015, water from a deteriorated roof drain pipe located near the ceiling leaks onto electrical equipment below during periods of heavy rain. Water from the leaking pipe accumulates in the F-Bus substation which houses energized panels (2300 volt). Employees required to enter the F-Bus substation to monitor electrical equipment during periods of heavy rain are exposed to the hazards of electric shock and electrocution.
Recent events (2)
- — I (S) $3750
- — Z (S) $5000
1910.305 G01 IV D
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and/or cables where attached to building surfaces: a) Compressor room, back side of 91 Line, 130 Lincoln Avenue, Vandergrift, PA 15690: Observed on or about June 18, 2015, a flexible cord (110 Volt) used to supply power to a lamp near the compressor was attached to building surfaces. The flexible cable ran from a wall outlet (110 Volt) located to the right of a 2300 Volt panel (marked F13), along the compressor room wall and ceiling, and down a pipe to the lamp. The flexible cable was fastened to metal conduit at several locations. Employees working in the compressor room, including those required to complete the Ingersol Rand Daily Log checklist, were exposed to the hazards of fire and electric shock. b) Inspection Line, 91 Line, back side of 91 Line, 130 Lincoln Avenue, Vandergrift, PA 15690: Observed on or about June 18, 2015, a flexible cord (110 Volt) was strung between a plug located to the left of the crane disconnect panel to the inspection room on the 91 Line. The flexible cord was strung over conduit, pipes, and through hand rail supports near the inspection room. Employees working in the area were exposed to the hazards of fire and electric shock. c) Behind Aux 91 Station, back side of 91 Line, 130 Lincoln Avenue, Vandergrift, PA 15690: Observed on or about June 18, 2015, an orange flexible cord (110 Volt) was strung along a wall on the back side of the Aux 91 station. The flexible cable was secured to the wall by the use of ties at multiple locations along its length. Employees working in the area were exposed to the hazards of fire and electric shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ALLEGHENY LUDLUM, LLC
LOUISVILLE, OH—2018-01-11 00:00:00
ALLEGHENY LUDLUM LLC
NEW BEDFORD, MA—2016-02-11 00:00:00
ALLEGHENY LUDLUM, LLC
LOUISVILLE, OH—2016-02-04 00:00:00
ALLEGHENY LUDLUM LLC
NEW BEDFORD, MA—2016-01-13 00:00:00
ALLEGHENY LUDLUM, LLC
LOUISVILLE, OH—2015-12-21 00:00:00
ALLEGHENY LUDLUM LLC
View ALLEGHENY LUDLUM, LLC's full OSHA safety record →
More inspections in this industry (NAICS 331221)
DEARBORN, MI—2026-06-29
BWD TECHNOLOGIES LLC
OAK GROVE, MO—2026-06-01
AXIAL CONCEPTS LLC.
GRAND RAPIDS, MI—2026-06-01
DENNEN STEEL LLC
SAUK VILLAGE, IL—2026-05-27
TARGET METAL BLANKING INC.
CHILLICOTHE, OH—2026-05-26
CHILLICOTHE STEEL COMPANY
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340764976.