Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WEAVER CONSTRUCTION AND ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WEAVER CONSTRUCTION AND ROOFING, INC. in 844 TUCK STREET, LEBANON, PA 17042 (NAICS 238160). OSHA activity number 340812981.

Watch Weaver Construction AND Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Weaver Construction AND Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
844 TUCK STREET
City
LEBANON
State
PA
ZIP
17042
Mailing
4873 DIVISION HWY, EAST EARL, PA 17519
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.451 C02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1820.00 Reduced
29 CFR 1926.451(c)(2)(v): Fork-lifts were used to support scaffold platforms while the entire platform was not attached to the fork and the fork-lift was moved horizontally while the platform was occupied:     a) 844 Tuck Street, Lebanon, PA; Employees were flashing around the chimney while working on a scaffold platform that was not attached to the Pettibone Model Number 6036, on or about 07/30/2015.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $1820
  • — C (S) $2800
  • — Z (S) $2800

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1820.00 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level:     a) a) 844 Tuck Street, Lebanon, PA; Employees were flashing around the chimney while working on a scaffold platform 12 feet above the ground without the use of fall protection, on or about 07/30/2015.       Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $1820
  • — C (S) $2800
  • — Z (S) $2800

1926.501 B10

Willful Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $44000.00 · Current $28600.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, or personal fall arrest system:     a) 844 Tuck Street, Lebanon, PA; Employees were installing a metal roof at heights between 10 and 13 feet above the ground without the use of fall protection, on or about 07/30/2015.       Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (3)
  • — F (W) $28600
  • — C (W) $44000
  • — Z (W) $44000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340812981.