Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARTIN DE LA TORRE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARTIN DE LA TORRE in 603 MOORER AVE, HARDEEVILLE, SC 29927 (NAICS 238170). OSHA activity number 340829332.

Watch Martin DE LA Torre — free Get an email when a new federal OSHA severe-injury report for Martin DE LA Torre is published. One employer, no account, unsubscribe in one click.
Establishment
MARTIN DE LA TORRE
Site address
603 MOORER AVE
City
HARDEEVILLE
State
SC
ZIP
29927
Mailing
603 MOORER AVE, HARDEEVILLE, SC 29927
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  a) Pooler residential construction site, on or about and at times preceding to August 5, 2015, a fall arrest system was not utilized for employees who were working from a pump jack scaffold while installing soffit, exposing employees to a 16-foot fall hazard.
Recent events (1)
  • — Z (S) $2000

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  (a) Pooler construction site, on or about and at times proceeding to August 5, 2015, pump jack scaffold was not secured to the structure at the bottom of the scaffold to prevent slippage and collapse.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    (a) Pooler construction site, on or about August 5, 2015, an employee who was installing soffit from a roof while exposed to a 9 foot fall hazard was not provided with fall protection.
Recent events (1)
  • — Z (S) $1600

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   (a) Pooler construction site, on or about and at times preceding to, August 5, 2015, employees were exposed to fall hazards in that an aluminum ladder, used to access the porch roof to install fascia and soffits, was extended only one foot past the roof edge.
Recent events (1)
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340829332.