WEST WINFIELD, NY —
OSHA Inspection: PRECISIONMATICS CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRECISIONMATICS CO., INC. in 100 HELMER AVENUE, WEST WINFIELD, NY 13491 (NAICS 332710). OSHA activity number 340889963.
Where did this inspection happen?
- Establishment
- PRECISIONMATICS CO., INC.
- Site address
- 100 HELMER AVENUE
- City
- WEST WINFIELD
- State
- NY
- ZIP
- 13491
- Mailing
- P. O. BOX 250, WEST WINFIELD, NY 13491
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 70
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1483.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At the establishment, on or about 9/1/15: Where employees perform servicing, maintenance or set up of various machinery and equipment, including, but not limited to CNC lathes and mills, air compressors, laser machines, etc., the employer had not established machine specific energy control procedures to prevent the unexpected energizing, start up or release of stored energy of the equipment. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1482.5
- — Z (S) $2975
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1483.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts and unused portion of blade: a) Swiss 1 Dept., on or about 9/1/15: Rotating chuck on a Bridgeport milling machine, Serial #125644, was not guarded. b) Material Room 1, on or about 9/1/15: Rotating nut projection and unused portion of sanding belt on a Kalamazoo belt sander were not guarded. c) Material Room 1, on or about 9/1/15: Unused portion of blade on a DoAll horizontal bandsaw was not guarded on the right side. d) Choke Deburring Dept., on or about 9/1/15: Rotating chuck on a Manhattan drill press was not guarded. e) Multi Task Dept., on or about 9/1/15: Rotating chuck on a Manhattan drill press was not guarded. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $1482.5
- — Z (S) $2975
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1035.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Maintenance Shop, on or about 9/1/15: Compressed air used for cleaning purposes measured 70 psi. b) Robot 1 Dept., on or about 9/1/15: Compressed air used for cleaning purposes at the Amada turning center WS109 measured 50 psi. c) Robot 1 Dept., on or about 9/1/15: Compressed air used for cleaning purposes at the Techno Wasino WS100 measured 50 psi. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $1035
- — Z (S) $1785
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Swiss 1 Dept., on or about 9/1/15: Extension cord providing current to a light fixture attached to the Black Diamond drill grinder was being used as permanent wiring. b) Back Maintenance Room, on or about 9/1/15: Extension cord providing current to a Rigid shop vac being used as a dust collection system for a Bosch table saw, was strung overhead and being used as permanent wiring. c) Swiss 1 Dept., on or about 9/1/15: Extension cord and three plug adapter providing power for various equipment for the Lasonall marker machine was being used as permanent wiring. d) Second Turn Dept., on or about 9/1/15: Extension cord and strip outlet at the Mazak Quick Turn 8N powering fans and portable equipment was strung overhead and being used as permanent wiring. Abatement certification must be submitted for these items.
Recent events (2)
- — I (O) $0
- — Z (S) $1785
1910.212 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Swiss 1 Dept., on or about 9/1/15: Black Diamond drill grinder was not secured to prevent walking or moving. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PRECISIONMATICS CO., INC.
WEST WINFIELD, NY—2024-10-09 00:00:00
PRECISIONMATICS CO., INC.
WEST WINFIELD, NY—2010-04-15 00:00:00
PRECISIONMATICS CO., INC.
WEST WINFIELD, NY—2007-03-14 00:00:00
PRECISIONMATICS CO., INC.
WEST WINFIELD, NY—2003-10-30 00:00:00
PRECISIONMATICS CO., INC.
WEST WINFIELD, NY—1989-04-17 00:00:00
PRECISIONMATICS CO., INC.
View PRECISIONMATICS CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
WIXOM, MI—2026-07-16
MANSON MANUFACTURING LLC DBA TOMCO MANUFACTURING
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLARKLAKE, MI—2026-07-15
CLARKLAKE MACHINE INC
MUSKEGON HEIGHTS, MI—2026-07-15
L. THOMPSON COMPANY LLC DBA TOTAL QUALITY MACHINING
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340889963.