ORCHARD PARK, NY —
OSHA Inspection: SHAMUS ROOFING, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of SHAMUS ROOFING, INC. in 3275 NORTH BENZING ROAD QUAKER CROSSING RETAIL CENTER, ORCHARD PARK, NY 14127 (NAICS 238160). OSHA activity number 340910611.
Where did this inspection happen?
- Establishment
- SHAMUS ROOFING, INC.
- Site address
- 3275 NORTH BENZING ROAD QUAKER CROSSING RETAIL CENTER
- City
- ORCHARD PARK
- State
- NY
- ZIP
- 14127
- Mailing
- 6 SCRIVNER DRIVE, CHEEKTOWAGA, NY 14227
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B10
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) On or about 9/8/15 at a new store construction project at the Quaker Crossing Retail Center located at 3275 North Benzing Road, Orchard Park, New York; employees installing roof insulation and materials were not protected from falling approximately 20 feet. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
1926.501 B11
- Issued
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 9/8/15 at a new store construction project at the Quaker Crossing Retail Center located at 3275 North Benzing Road, Orchard Park, New York; employees were installing underlayment on a roof with a 6 in 12 pitch and an unprotected edge of more than 20 feet. There were no fall protection systems in place. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.1053 B01
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 9/8/15 at a new store construction project at the Quaker Crossing Retail Center located at 3275 North Benzing Road, Orchard Park, New York; a step ladder used for access to the roof was leaned against the wall and under the eaves. Employees had to climb around the eaves to access the roof. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1600
- — Z (S) $1600
1926.1053 B04
- Issued
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about 9/8/15 at a new store construction project at the Quaker Crossing Retail Center located at 3275 North Benzing Road, Orchard Park, New York; a step ladder used for access to the roof was leaned against the wall and wasn't open with the spreaders open and locked as designed. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $1600
More inspections at SHAMUS ROOFING, INC.
ORCHARD PARK, NY—2017-10-19 00:00:00
SHAMUS ROOFING, INC.
ORCHARD PARK, NY—2015-12-02 00:00:00
SHAMUS ROOFING, INC.
NIAGARA FALLS, NY—2014-04-21 00:00:00
SHAMUS ROOFING, INC.
View SHAMUS ROOFING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source