SHAWANO, WI —
OSHA Inspection: WISCONSIN FILM & BAG INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WISCONSIN FILM & BAG INC. in 3100 E RICHMOND ST, SHAWANO, WI 54166 (NAICS 326111). OSHA activity number 341038214.
Where did this inspection happen?
- Establishment
- WISCONSIN FILM & BAG INC.
- Site address
- 3100 E RICHMOND ST
- City
- SHAWANO
- State
- WI
- ZIP
- 54166
- Mailing
- 3100 E RICHMOND ST, SHAWANO, WI 54166
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326111
- Employees
- 175
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.334 A02 I
- Issued
- Abate by
- Penalty
- Initial $4250.00 · Current $2975.00 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) On or about 11/4/2015, flexible cords were found during the inspection that were damaged with broken outer covers.
Recent events (2)
- — I (S) $2975
- — Z (S) $4250
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about 11/4/2015, an outlet box near the control panel for Line #2 was missing knockout covers. b) On or about 11/4/2015, an electrical junction box was missing a cover above the 480 volt extruder drive for line #3.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) On or about 11/4/2015, strain relief cables were not secured at the ceiling for pendants above line #4.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about 11/4/2015, the air wand for cleaning and separating plastic bags on line #2 was rated at 85 p.s.i. and did not have a relief tip on the air wand that would reduce the pressure to 30 p.s.i.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at WISCONSIN FILM & BAG INC.
SHAWANO, WI—2024-08-06 00:00:00
WISCONSIN FILM & BAG, INC.
SHAWANO, WI—2013-07-03 00:00:00
WISCONSIN FILM & BAG INC
Oconto, WI—1984-02-07
WISCONSIN FILM & BAG INC
Oconto, WI—1983-05-23
WISCONSIN FILM & BAG INC
Oconto, WI—1976-05-12
WISCONSIN FILM & BAG INC
View WISCONSIN FILM & BAG INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326111)
TRAVERSE CITY, MI—2026-05-28
PLASCON INC
NEWARK, NJ—2026-05-21
NAP INDUSTRIES GROUP LLC
SAINT PAUL, MN—2026-05-19
111301 - REVOLUTIONS SUSTAINABLE SOLUTIONS LLC
SENOIA, GA—2026-04-29
WINPAK FILMS INC.
PISCATAWAY, NJ—2026-04-28
ALL AMERICAN POLY CORPORATION
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341038214.