PALMER, MA —
OSHA Inspection: WELLMAN HEALTHCARE GROUP, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of WELLMAN HEALTHCARE GROUP, INC. in 250 SHEARER ST, PALMER, MA 01069 (NAICS 623110). OSHA activity number 341081107.
Where did this inspection happen?
- Establishment
- WELLMAN HEALTHCARE GROUP, INC.
- Site address
- 250 SHEARER ST
- City
- PALMER
- State
- MA
- ZIP
- 01069
- Mailing
- 250 SHEARER ST ATTN: DAVID CAVALIER, PALMER, MA 01069
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 623110
- Employees
- 71
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.1001 J01 III
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.1001(j)(1)(iii): Employers did not include asbestos in the hazard communication program established to comply with the HCS (� 1910.1200). On or about November 24, 2015, the employer had not included asbestos in the hazard communication program to comply with the hazard communication standard �1910.1200. Asbestos Containing Material was found in the boiler room pipe insulation.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
1910.1001 J04 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1001(j)(4)(iv): At the entrance to mechanical rooms/areas in which employees reasonably can be expected to enter and which contain ACM and/or PACM, the building owner did not post signs which identified the material present, its location, and appropriate work practices which, if followed, will ensure that ACM and/or PACM will not be disturbed. On or about November 24, 2015, the employer had not posted signs to identify the areas in the boiler room where pipe insulation contained asbestos.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1001 J03 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.1001(j)(3)(i): Building and facility owners did not determine the presence, location, and quantity of ACM and/or PACM at the work site. Employers and building and facility owners did not exercise due diligence in complying with these requirements to inform employers and employees about the presence and location of ACM and PACM. On or about November 24, 2015, the employer had not determined the presence, location, and quantity of Asbestos Containing Material (ACM) or Potential Asbestos Containing Material (PACM.) Hard white pipe insulation in the boiler room was determined to contain Chrysotile Asbestos.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.1001 J07 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $2000.00
General-duty citation text
29 CFR 1910.1001(j)(7)(iv): The employer did not provide, at no cost to employees who perform housekeeping operations in an area which contains asbestos containing material(ACM) or potential asbestos containing material( PAC, an asbestos awareness training course, which shall at a minimum contain the following elements: health effects of asbestos, locations of ACM and PACM in the building/facility, recognition of ACM and PACM damage and deterioration, requirements in this standard relating to housekeeping, and proper response to fiber release episodes. Each such employee was not so trained at least once a year. On or about November 24, 2015, the employer had not provided an asbestos awareness training to employees who performed housekeeping operations in areas that contained ACM or PACM in the boiler room.
Recent events (2)
- — I (S) $2000
- — Z (S) $0
More inspections in this industry (NAICS 623110)
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
MINNEAPOLIS, MN—2026-07-16 00:00:00
111617 - CRESTVIEW RESIDENCE LLC
WOODLAND, CA—2026-07-13 00:00:00
THE GROVE POST-ACUTE
MILTON FREEWATER, OR—2026-07-09 00:00:00
317744637 - EVERGREEN OREGON HEALTHCARE ORCHARDS RETIREMENT LL
GRANTS PASS, OR—2026-07-07 00:00:00
317744714 - CASCADE LIVING GROUP - GRANTS PASS LLC
More inspections in MA
WESTFORD, MA—2026-07-17 00:00:00
M&M CONSTRUCTION SERVICES CORP